ECI3808 Network Motion Control Card User Manual V1.5
→
Wiring Note:
ECI3808 control card uses the single power, and ZIO expansion module uses dual-
power. When using, main power supply of expansion module and main power supply
of controller can share one power. When they use different power supplies, controller
power EGND needs to connect to expansion module power GND, otherwise CAN may
be burnt out.
When connecting multiple ZIO expansion modules on the CAN bus, a 120-ohm
resistor needs to be connected in parallel between the CANL and CANH terminals, for
the ZIO expansion module that is with 8-digit dialing codes, the terminal resistor can
be realized by dialing the code (DIP).
4.2.
CAN Bus Expansion Resource Mapping
The ZCAN expansion module generally has an 8-bit DIP switch, dial ON to take effect,
and the meaning of the DIP is as follows:
1-4: they are used for ZCAN expansion module IO address mapping, the
corresponding value is 0-15.
5-6: CAN communication speed, corresponding value is 0-3, four different speeds are