Wiring Note:
⚫
For the connection of the public end, please connect the "EGND" port on the power
supply to the negative pole of the DC power supply of the external input device. If the
DC power supply of the external device and the controller power supply are in the
same power supply system, this connection can also be omitted.
3.5.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use ETHERNET, RS232 or RS485 to connect to ZDevelop.
(3)
Open or close output port directly through “OP” command, also, it can be opened or
closed through “ZDevelop/View/Op”. Please refer to “ZBasic” for details.
(4)
The PWM function, set the frequency and duty cycle through
“PWM_FREQ” and
“PWM_DUTY”. Please refer to ZBasic for details.
3.6.
AD/DA: Analog Input / Output
The control card provides one analog input / output, which includes 4 ADs and 2 DAs,
each interface is standard DB9 female socket.