ZLIS42C Integrated Step-Servo Motor Manual Version 1.10
ZLIS42C Integrated Step-Servo Motor Manual Version 1.10
7
Shenzhen ZhongLing Technology Co.,Ltd. TEL: +86-0755-29799302 FAX
:
+86-0755-2912 4283 WEB:
Shenzhen ZhongLing Technology Co.,Ltd. TEL: +86-0755-29799302 FAX
:
+86-0755-2912 4283 WEB:
■
4 DIP switch selection, 16-segment step resolution;
■
With over-voltage, over-current, out of tolerance protect function etc;
■
With built-in 2500-wire magnetic encoder, provides real-time feedback of motor
running state.
1.3. Application
Suitable for all kinds of small automation equipment and instruments, such as:
pneumatic marking machine, labeling machine, cutting machine, laser marking machine,
plotter, small engraving machine, CNC machine tool, pick and place device. It is
particularly effective in applications where users expect low noise, low vibration, high
stationarity and high precision.
2.
ELECTRICAL, ENVIRONMENTAL INDEX
2.1.
Electrical Index
Driver Parameter
Min value
Typical value
Max value
Unit
Input voltage
20 VDC
24VDC
50VDC
V
Output current(peak)
0
1.5
2.2
A
Control signal input
current
7
10
16
mA
Over-voltage
protection
-
55
-
VDC
Input signal voltage
-
5
-
VDC
Insulation resistance
100
MΩ
Encoder resolution
2500
Wires
Holding
torque
L=70mm
0.48
N.m
L=82mm
0.72
2.2.
Environmental Index
Cooling Type
Natural cooling or forced cooling
Working
environment
Application occasion
Avoid dust, oil mist and corrosive gases
Working temperature
0~50
℃
Max. ambient humidity
90% RH(no condensation)
Storage temperature
-10~70
℃
Vibration
10~55Hz/0.15mm
2.3.
Installation Diagram
Fig.1 Installation dimension diagram (Unit: mm)
There are 2 options for L:70mm, 82mm. 2 options for
∅
D: 5mm, 8mm.
2.4.
Installation
User could mount with the mounting holes on the front of the integrated
step-servo motor. Use M3 screw to install through the holes in the four corners.
The integrated step-servo motor will generate heat. If continuous operation is
under high input voltage and high power conditions, the effective heat dissipation
area or forced cooling should be expanded. Do not use in places where air is not
circulating or where the ambient temperature exceeds 60
℃
; do not install it in a
place that is wet or has metal shavings.