5
Installation
INSTALLATION
Unit Connection Cord
Unit Connection Cord
Single and dual-motor remote blowers are designed to reduce noise by installing them in a
separate location inside the home, up to 20' (6096 mm) away from the range hood.
T85 Remote Blower — Single Motor
• This motor must be used with remote blower range hood
• Airflow: 400 (CFM)
• Noise Level: 1.2 / 2.6 / 4.2 / 6.5 (Sones)
• Dimensions: 26 1/8" W x 14 5/8" D x 13" H (667 mm x 371 mm x 330 mm)
T95 Remote Blower — Dual Motor
• This motor must be used with remote blower range hood
• Airflow: 280 / 460 / 670 / 700 (CFM)
• Noise Level: 1.2 / 2.8 / 5.0 / 7.0 (Sones)
• Dimensions: 26 1/8" W x 14 5/8" D x 13" H (667 mm x 371 mm x 330 mm)