13
12
Gas Conver
sion Pr
ocedur
e
GAS CONVERSION PROCEDURE
The gas conversion procedure for this range includes:
1. Pressure Regulator
2. Surface Burners
3. Flame Adjustment
The conversion is not finished if all steps are not completed.
Before performing the gas conversion, locate the package containing the
replacement nozzles, which has a number indicating its flow diameter printed on the
body. Consult the table below for matching nozzles to burners.
Save the nozzles removed from the range for future use.
LPG: Liquid Propane Gas
NG: Natural Gas
INSTALLATION
Gas Connection
STEP 1: PRESSURE REGULATOR
The pressure regulator supplied with the appliance is a convertible type pressure
regulator for use with Natural Gas at a nominal outlet pressure of 4˝ w.c. or LP gas
at a nominal outlet pressure of 11” w.c. and it is pre-assembled from the factory
to operate with one of these gas pressure as indicated in the labels affixed on the
appliance, package, and instruction booklet.
To convert the regulator for use with other liquid propane LP gas:
1. Unscrew the front cap of the regulator (as seen below.) Inside the cap is a screw.
By hand, remove the screw to reveal a spring. Reapply the screw to the cap with
the spring revealed.
2. With the spring sticking out of the cap, reapply back to the regulator.
Any issues related to improper propane conversion are NOT covered
under warranty.
WARNING
5/8
Rever
se r
egulator
scr
ew and spring.
Gas Conversion Procedure
Propane
Natural Gas
INSTALLATION
Gas Conver
sion Pr
ocedur
e