BEFORE INSTALLATION
WATER SYSTEM LOCATION
• The water connected to the dual refrigeration unit must be potable.
• Location of the water system must be within the range outlined in the graphic at the
bottom of this page.
• The unit's water system must be connected to the main water system in the house. The user
must be able to switch the water system on/off with a valve when necessary.
• Objects that might pierce the water hoses or cause them to twist must not be present
where the water line is installed.
• Pressure of the water system must be between 25-80 psi (1.7-5.5 Bar).
• If the water pressure exceeds 80 psi, install a pressure-limiting device or water pressure
protector to the inlet valve. Never install or operate the appliance if it's possible for the
water pressure to exceed 120 psi.
• Make sure there is no leakage when making water connections.
Otherwise, there will be water on the floor and the cabinets may
get damaged.
• You will need a hose with a minimum length of 60" (1524 mm)
and a diameter of 1/4" (6.4 mm) for water connections of the
product during installation.
• A connector that has a thread with an external diameter of 1/4"
(6.4 mm) must be used to connect the hose end to the product.
• Before completing installation, make sure water flows and there is
no leakage. Damage may occur if leaks are present.
WARNING
2” (50.8 mm)
10” (254 mm)
20” (508 mm) 10” (254 mm)
13/16” (
21 mm)
4” (
102 mm)