Continued
Category
Name
Default
Description
CAN
configura
tion
Destination
port 1
8001/8002
Available values are 1 to 65535. Only valid in
TCP Client and UDP working modes. Used to
define the port of the network device that
communicates with the CANSwitch-AF2S2
device. Only the network data sent through this
port can be received by the CANSwitch-AF2S2
device, and the data frame received by the
CAN port of the CANSwitch-AF2S2 device will
also be sent to this port through the optical
fiber. The default CAN0 destination port 1 is
8001, and the default CAN1 destination port 1
is 8002.
Subnet mask 1
255.255.255.0
The subnet mask determines whether the host
number of the network and whether the host
number is legal, such as the network segment
192.168.1.x.
If
the
subnet
mask
is
255.255.255.0, the IP 192.168.1.255 is a
broadcast address and cannot be used to
represent a host.But if the subnet mask is
255.255.0.0, 192.168.1.255 is an illegitimate
device address
Start address
1
192.168.0.55
Only valid in TCP Client and UDP working
modes. It is used to define the destination IP
address; that is, the port IP address of the
network device that communicates with the
CANSwitch-AF2S2 device (it can also be the
starting IP address in the IP address segment).
End address 1
192.168.0.55
Only valid in TCP Client and UDP working
modes. Used to define the end IP address in
the IP address segment. If there is only one
destination address, the end address can be
the same as the start address.
Note: If the IP address segment is filled in the
end address, multiple network devices will
communicate with CANSwitch-AF2S2 at the
same time. The first three bytes of the IP
address segment must conform to the subnet
mask 1 limit, and the fourth byte of the ending
address must be greater than or equal to the
fourth byte of the starting IP address.