frames/s, and the CANFD single-channel standard frame rate can reach 4,600
frames/s;
When only the relay is used, the forwarding delay is about 40 us. When frame
mapping and merging and splitting functions are used at the same time, the
forwarding delay is about 50 us. The more frame mapping, merging and splitting rules,
the greater the forwarding delay. The forwarding delay is also affected by the baud
rate. When the baud rate value is small, such as 50 kbps, the forwarding delay is up
to 60 us;
The CAN-bus circuit adopts 2,500 V DC electrical isolation;
Can be used in environments with safety and explosion-proof requirements;
Operating temperature: -40
℃
to +85
℃
; Operating power: less than 2 W;
1.3 Typical Applications
Coal mine telecommunication;
Industrial site control;
Remote monitoring and data collection;
Electrical communication;