Random alarm
Select
Random alarm
on the Alarm setting interface, and press
OK
to enter the random alarm
setting interface, as shown in the following:
Under normal circumstances, the alarm is generated when the amount of metal signal
reaches the set sensitivity threshold, while it can pass normally when it is less than the
threshold. When a random alarm value is set, there will be a n% probability that a normal pass
without alarm will be turned into an alarm, so that it can be checked and confirmed again
manually.
Operation:
Press the
[OK]
button to enter the random alarm setting interface, then press the
[
▲
]/ [
▼
]
button to increase or decrease the value, press
[OK]
button to save and exit to the upper menu after
finishing, directly press
[
⏎
]
button to exit to the upper menu without saving the current value.
Alarm Mode
Select
Alarm Mode
on the Alarm setting interface, and press
OK
to enter the alarm mode
setting interface, as shown in the following: