30
ULTIMA
INSTALLATION GUIDE | 2019 - v1
Issue
Probable Causes
Corrective Action
There is no power in the Ultima.
If the Ultima is powered using standard AC power cable, the
power supply is not properly plugged into the main board, the
AC outlet, or both.
Check the connections to the main board and the AC outlet.
Note: Do not plug the power cord into the AC outlet until you en-
sure that the power supply is properly connected to the main board.
If the Ultima is powered using Ethernet cable, the network may
be down, or connections to and from the PoE module may not
be secure.
• Ensure that the network is running.
• Ensure that the network cable is connected to the main board.
The power LED is turned on, but
nothing appears on the screen.
If the Ultima is powered using a standard AC power cable, the AC
line is not live or is supplying improper voltage.
Measure voltage at the AC outlet and, if necessary, locate another
power source.
If the Ultima is powered using Ethernet cable, there is an issue
with the network.
• Check the Ethernet connection at the Ultima, and all other net-
work connections.
• Ensure that the network is supplied with an 802.11af-compliant
power source.
Communication fails.
Communication settings are incorrect either at the Ultima or the
host PC.
Check and, if necessary, correct the device IP Address, Netmask,
Gateway and DNS.
Communications cabling is connected incorrectly.
Ensure that all communications cables are routed correctly and
connected properly.