5  Troubleshooting

Symptom

Troubleshooting

The indicator is not lighted when the 
equipment is powered on.

It may be caused by the power supply or circuit. 
Check  whether  the  connection  cable  and  power  cable 
between are damaged, or the wiring is loose. 

The  arms  of  the  tripod  turnstile 
cannot  be  lifted  manually  after  the 
equipment is powered on.

It may be caused by the problem of relative components 
or drop-arm solenoid. 
Check  whether  the  drop-arm  solenoid  is  operating,  and 
check the work status of the solenoid, as shown in Figure 
4-1. 

The tripod turnstile does not open 
after authentication.

It may be caused by lack of permission or a circuit problem.

Check whether the user has the permission to open the 
turnstile.

Use  a  multimeter  to  check  whether  the  NO  and  COM 
ports  of  the  access  control  system  has  a  relay  signal 
output.

Short-circuit  the  ports  "K1,  GND"  and  "K2,  GND",  if  the 
turnstile  is  successfully  opened,  it  would  be  the 
problem of controller.

1

.

2

.

3

.

The turnstile allows people continue 
passing  one-way  side  during  the 
use.

Check the Turnstile-opening Solenoid.

Check  the  access  controller  'Lock  driving  duration', 
whether set to 1s.

Check  whether  the  Turnstile -opening  solenoid  is 
operating  and  check  whether  the  Turnstile-opening 
solenoid is stuck, as shown in Figure 4-1.

1

.

2

.

3

.

6

Содержание TS1000 Pro Series

Страница 1: ...able Models TS 1000 2000 Pro series Tripod Turnstile Version 1 1 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual ...

Страница 2: ...1 Figure 1 1 1 2 Cabling 1 3 Drilling Holes Drill holes based on the locations of the screw holes Fix the device on the ground by 4 expansion screws 1 4 Fix the Device Power supply and communication wire suggested to deployed underground then into the cabinet of device Note The tripod turnstile must be connected to the Ground earth there is wiring interface near the power switch ...

Страница 3: ...s shown in Figure 2 1 Figure 2 1 2 Please make sure that the power requirements are strictly met to avoid permanent damage to the unit Input voltage AC 100 120V 200 240V Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arm manually as shown in Figure 2 2 4 Push arm Lift upwards Figure 2 2 Note If the arm can not be lift please push the arm to close to cabin...

Страница 4: ...ent in this chapter carefully 3 1 Function Description of the Turnstile Control Board Turnstile control board s diagram as shown in Figure3 1 Counter Counter Left direction indicator Right direction indicator Passing indicator Opening signal input External alarm drop arm RS485 port 12V DC output Proximity sensor signal input 24V DC input Right solenoid Left solenoid Drop arm solenoid ...

Страница 5: ... 1 second or less than 1 second 3 2 Connection Diagram of the Access Controller Note The lock relay duration of access controller device needs to be set to 1s Forbidden using electrically charged objects to connect to the port of Opening Signal Input otherwise will damage the control board ...

Страница 6: ...intenance consciousness Regular maintenance Cleaning and protection liquid dedicated for stainless steel are recommended to wipe the outer shell of the equipment regularly The tripod turnstile used outdoors or in an environment with lots of dust must be maintained once a year at least for example clean up the dust and add appropriate lubricating oil to Disk Wheel Note regular maintenance should be...

Страница 7: ...ripod turnstile does not open after authentication It may be caused by lack of permission or a circuit problem Check whether the user has the permission to open the turnstile Use a multimeter to check whether the NO and COM ports of the access control system has a relay signal output Short circuit the ports K1 GND and K2 GND if the turnstile is successfully opened it would be the problem of contro...

Страница 8: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved ...

Отзывы: