Figure3-1

Note: 

The third party access control system lock relay trigger time should be 1 second or less than 1 

second.

3.2 Connection Diagram of the Access Controller

Note:

  The  lock  relay  duration  of  access  controller  device  needs  to  be  set  to  1s.  Forbidden  using 

electrically charged objects to connect to the port of Opening Signal Input, otherwise will damage 
the control board.

Содержание TS1000 Pro Series

Страница 1: ...able Models TS 1000 2000 Pro series Tripod Turnstile Version 1 1 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual ...

Страница 2: ...1 Figure 1 1 1 2 Cabling 1 3 Drilling Holes Drill holes based on the locations of the screw holes Fix the device on the ground by 4 expansion screws 1 4 Fix the Device Power supply and communication wire suggested to deployed underground then into the cabinet of device Note The tripod turnstile must be connected to the Ground earth there is wiring interface near the power switch ...

Страница 3: ...s shown in Figure 2 1 Figure 2 1 2 Please make sure that the power requirements are strictly met to avoid permanent damage to the unit Input voltage AC 100 120V 200 240V Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arm manually as shown in Figure 2 2 4 Push arm Lift upwards Figure 2 2 Note If the arm can not be lift please push the arm to close to cabin...

Страница 4: ...ent in this chapter carefully 3 1 Function Description of the Turnstile Control Board Turnstile control board s diagram as shown in Figure3 1 Counter Counter Left direction indicator Right direction indicator Passing indicator Opening signal input External alarm drop arm RS485 port 12V DC output Proximity sensor signal input 24V DC input Right solenoid Left solenoid Drop arm solenoid ...

Страница 5: ... 1 second or less than 1 second 3 2 Connection Diagram of the Access Controller Note The lock relay duration of access controller device needs to be set to 1s Forbidden using electrically charged objects to connect to the port of Opening Signal Input otherwise will damage the control board ...

Страница 6: ...intenance consciousness Regular maintenance Cleaning and protection liquid dedicated for stainless steel are recommended to wipe the outer shell of the equipment regularly The tripod turnstile used outdoors or in an environment with lots of dust must be maintained once a year at least for example clean up the dust and add appropriate lubricating oil to Disk Wheel Note regular maintenance should be...

Страница 7: ...ripod turnstile does not open after authentication It may be caused by lack of permission or a circuit problem Check whether the user has the permission to open the turnstile Use a multimeter to check whether the NO and COM ports of the access control system has a relay signal output Short circuit the ports K1 GND and K2 GND if the turnstile is successfully opened it would be the problem of contro...

Страница 8: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved ...

Отзывы: