SpeedFace M4
User Manual
P a g e
| 60
Copyright©2021ZKTECO CO., LTD. All rights reserved.
9.1
Access Control Options
This option is used to set the parameters of the control lock of the device and the related parameters.
Click
Access Control Options
on the Access Control interface.
Function Name
Description
Gate Control Mode
It toggles between
ON
or
OFF
switch to get into gate control mode or not.
When set to
ON
, the interface removes the Door lock relay, Door sensor relay,
and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1 to 10 seconds; 0 seconds represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three Sensor types:
None, Normal Open,
and
Normal Closed
.
None:
It means the door sensor is not in use.
Normally Open:
It means the door is always left open when electric power is on.
Normally Closed:
It means the door is always left closed when electric power is on.
Verification Mode
The supported verification mode includes password/face, User ID only,
password, face only, and face + password.