SBTL300 Series
User Manual
P a g e
| 12
14 14EXXX Memory function
0 -- Closing memory
function (default: 0)
1 -- Opening memory
function
15 15EXXX Swiping card mode
0 -- Allow to swipe
card in passage
(default: 0)
1 -- Not allow to
swipe card in passage
16 16EXXX Volume setting
0~31 (default: 20)
The higher the value, the louder
the sound
17 17EXXX Alarm mode
0 -- Opening alarm
voice (default: 0)
1 -- Closing alarm
voice
18 18EXXX
Exchange entrance
and exit voice
0 -- Right entrance,
left exit (default: 0)
1 -- Left entrance,
right exit
19 19EXXX
Traffic detention
alarm time
5~30 (default: 10)
Unit: s
20 20EXXX Intensity adjustment 10~60 (default: 40)
The greater the value, the greater
the force
21 21EXXX Fire signal setting
0 -- Right opening
(default: 0)
1 -- Left opening
22 22EXXX
Failure to pass
infrared completely,
delay closing time
5~60 (default: 15)
23 23EXXX Reset
1
–
Reset (default: 0)