SBTL300 Series
User Manual
P a g e
| 11
7 -- right prohibition,
left free
8 -- right controlled,
left free
3
03EXXX
Speed of barrier
opening
0~30 (default: 15)
The higher the number, the faster
the speed
4
04EXXX
Opening brake
stroke
10~25 (default: 25)
The larger the number, the
longer the deceleration time and
the smoother the swing arm
5
05EXXX
Brake speed of
opening
0~30 (default: 10)
The larger the number, the
slower the speed when
decelerating, and the more stable
the swing arm is
6
06EXXX
Speed of barrier
closing
0~30 (default: 15)
The higher the number, the faster
the speed
7
07EXXX Closing brake stroke 10~25 (default: 25)
The larger the number, the
longer the deceleration time and
the smoother the swing arm
8
08EXXX
Brake speed of
closing
0~30 (default: 10)
The larger the number, the
slower the speed when
decelerating, and the more stable
the swing arm is
9
09EXXX
Master and vice
machines Setting
0 -- master (default:
0) 1 -- vice
10 10EXXX RS485 address
0~250
11 11EXXX Open duration
0~60 (default: 5)
Unit: s
12 12EXXX
Gate closing delay
time
0~60 (default: 0)
Unit: s
13 13EXXX Barrier positioning
1 -- Zero position
(default)
2 -- Left opening
position
3 -- Right opening
position
4 -- Vice opening
position
The corresponding position can
only be adjusted in place