background image

SBTL300 Series

 

 

 

 

 

 

 

   

User Manual 

P a g e

 | 1 

 

Copyright© 2020 ZKTECO CO., LTD.  All rights reserved. 

Thank you for choosing our product. Please read the instructions carefully 
before operation. Follow these instructions to ensure that the product is 
functioning properly. The images shown in this manual are for illustrative 
purposes only. 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Swing Barrier-SBTL300 Series 

Date: September 2020 

Doc Version: 1.0 

English 

Содержание SBTL300 Series

Страница 1: ...oosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only User Manual Swing Barrier SBTL300 Series Date September 2020 Doc Version 1 0 English ...

Страница 2: ...l P a g e 1 About the Manual This manual introduces the operations of SBTL300 Series product All figures displayed are for illustration purposes only Figures in this manual may not be exactly consistent with the actual products ...

Страница 3: ...es for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in performing the operations f...

Страница 4: ... THE PRODUCT 5 SPECIFICATION 6 2 INSTALLATION OF THE PRODUCT 7 INSTALLATION NOTES 7 INSTALLATION POSITION OF THE SWING BARRIER 7 CABLES INSTALLATION AND FIXING 8 3 MENU INTRODUCTION 9 FUNCTION INTRODUCTION 9 OPERATING INSTRUCTIONS 10 MENU INTRODUCTION 10 4 TROUBLESHOOTING 13 5 PRODUCT MAINTENANCE 13 CHASSIS MAINTENANCE 13 MOVEMENT MAINTENANCE 13 POWER MAINTENANCE 14 APPENDIX INTERNAL WIRING DIAGRA...

Страница 5: ...using which provides simple and beautiful design with corrosion protection It provides legal access to the persons and restricts illegal personnel access In case of emergency it ensures that evacuation passage runs smoothly and is convenient for personnel SBTL300 s appearance and dimensions are shown in Figure 1 1 Figure 1 1 ...

Страница 6: ...gnals and sends executive commands to the direction indicator the electric motor and the alarm Infrared sensor It detects the position of a pedestrian and plays the role of safety protection Direction indicator This indicator displays the pedestrian passage path and directs them to pass through the lane in a safe and orderly manner Alarm The alarm gives an alarm voice if the system detects any una...

Страница 7: ...ion RS485 Input voltage AC110 240V 50 60Hz Input control signal Switching signal Output voltage DC 24V Time of opening closing 0 8 Sec adjustable Relative humidity 20 95 Non condensing Temperature 28 to 60 Passage rate Maximum 30 minute Infrared sensor 4 Working environment Indoor J4 888 888 DEC ADD MODE MEUN GND C D S 5V ...

Страница 8: ... check if the connection is done correctly at the connecting points of the protective ground wire at the connector assemblies and wiring points of the circuits as well as at each movable part of the swing barrier turnstile Any loose nuts screws and other fasteners should be tightened in time to avoid swing barrier turnstile failures caused by longer operations Installation Position of the Swing Ba...

Страница 9: ...duit SBTL 300 series installation holes and cabling positions is shown in Figure 2 2 Figure 2 2 Mark the screw hole at the centre of the stand and the edge of the chassis base on the ground according to the sizes as shown on the Figure 2 2 Use a hammer drill to make M12 screw holes and then install the screws Place the swing barrier turnstile according to the sizes and positions as shown in the fi...

Страница 10: ...fic two way traffic infrared switch on or pass control through the main board switch on signal additional control system access control fingerprint etc can be set through the main board menu 4 It has the function of automatic reset when the passer fails to pass within the specified time after receiving the opening signal the system will automatically cancel the current access authority of the user...

Страница 11: ...nu function value options which can adjust function parameters up and down After adjustment long press the first key to save parameters Short press the first or second key to open the brake manually Menu Introduction Item Name Menu Function Description 1 01EXXX Display mode 0 display the current position of barriers default value 0 1 infrared input signal 2 control input signal 3 Test Mode Display...

Страница 12: ...ault 15 The higher the number the faster the speed 7 07EXXX Closing brake stroke 10 25 default 25 The larger the number the longer the deceleration time and the smoother the swing arm 8 08EXXX Brake speed of closing 0 30 default 10 The larger the number the slower the speed when decelerating and the more stable the swing arm is 9 09EXXX Master and vice machines Setting 0 master default 0 1 vice 10...

Страница 13: ...7 17EXXX Alarm mode 0 Opening alarm voice default 0 1 Closing alarm voice 18 18EXXX Exchange entrance and exit voice 0 Right entrance left exit default 0 1 Left entrance right exit 19 19EXXX Traffic detention alarm time 5 30 default 10 Unit s 20 20EXXX Intensity adjustment 10 60 default 40 The greater the value the greater the force 21 21EXXX Fire signal setting 0 Right opening default 0 1 Left op...

Страница 14: ...ut the rotated angle is not sufficient so it may cause loosening of belt 5 When powered ON the swing doesn t return to the initial position Ensure that no obstacle is in the sensing area then restart the equipment 5 Product Maintenance Chassis Maintenance The chassis is made up of SAE 304 stainless steel If it is in service for a longer period then there may be rust stains on its surface regularly...

Страница 15: ...r supply insulation periodically Do periodic check for any king of leakage Check if the technical parameters of interface are normal Check the service life of the electronic components and replace accordingly Caution Above mentioned maintenance method for swing barrier must be carried out by professional personnel Especially the movement and the electric control part first switch off the power sup...

Страница 16: ...SBTL300 Series User Manual P a g e 15 Appendix Internal Wiring Diagram ...

Отзывы:

Похожие инструкции для SBTL300 Series