Installation Diagrams 

 

2

 

Wiring 

Warning: 

Do not connect wires when the power is on! 

Note:  

 This device supports normally open (NO) and normally close (NC) locks which can be connected to 

different terminals for different functions. 

 At the moment when the electric lock is turned on or off, the electric lock generates a self-induced 

electromotive force. To prevent the impact of the self-induced electromotive force on the access control 
system, it is necessary to connect an FR107 diode in parallel to the electric lock during wiring on the access 
control system to release the self-induced electromotive. The FR107 diode is randomly provided. Do not 
reverse its positive and negative poles. 

 If an extension cable needs to be connected between the all-in-one device and the controller, we 

recommend that you use a Category 6 or above unshielded network cable; otherwise, voltage drop may 
occur on the extension cable, resulting in an unstable card reading effect. 

In the arrow directions shown 
above, remove the screws, and 
remove the rear hanging plate from 
the device 

Place the side of the rear hanging 
plate with screw holes downward 

Align the screw holes on the rear 
hanging plate with the holes drilled 
on the wall, and fix the rear hanging 
plate onto the wall with screws 

Sort out and connect the cables, 
and install the device onto the 
rear hanging plate 

Use the screws removed in Step 1 
to fix the device onto the rear 
hanging plate 

Pass the device cables through 
the wall and install them 

Содержание SA40

Страница 1: ...read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For fur...

Страница 2: ...design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equipment...

Страница 3: ...unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible i in case the machine unit equipment malf...

Страница 4: ...ndent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication f...

Страница 5: ...ion Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are sepa...

Страница 6: ...TD All rights reserved Table of Contents 1 INSTALLATION DIAGRAMS 6 2 WIRING 6 3 BASIC CONCEPTS 9 DESCRIPTION OF KEYS 9 3 1 CARD CATEGORIES 9 3 2 USER CATEGORIES 10 3 3 WIRING DEFINITION 10 3 4 4 OPERA...

Страница 7: ...R107 diode is randomly provided Do not reverse its positive and negative poles If an extension cable needs to be connected between the all in one device and the controller we recommend that you use a...

Страница 8: ...1 2 The device and the lock do not share the power supply as shown in Figure 1 2 Note ULOCK 12 V and I IDEVICE ILOCK Or ULOCK 12 V Or the lock is far from the device Figure 1 2 I indicates the output...

Страница 9: ...connected directly to the main board The operating current is equal to or less than 200mA and the standby current is equal to or less than 150mA The power supply can work after its positive and negati...

Страница 10: ...ard 1 The installation card is the first card that is swiped after initialization 2 When the installation card is swiped once it enters the card adding mode If you swipe a user card this card is added...

Страница 11: ...door only by both swiping the card and entering the password Wiring Definition 3 4 Access Control Mode Wiring Red DC 12V Black GND Blue NC normally close Orange COM common Gray NO normally open Purple...

Страница 12: ...tate 4 Set General Door Opening Password Press administrator password 9 enter a password of 4 6 digits For example 1234 9 123456 Note The default administrator password is 1234 and the default general...

Страница 13: ...assword must contain 4 6 digits 2 After a password based user is added you can continue to enter the user password to consecutively add password based users and press to exit the state 10 Add a Card a...

Страница 14: ...cally You can press to exit the state 12 Delete All Users You can delete all users by using two methods 1 Press administrator password 5 For example 1234 5 2 In standby state swipe the administrator c...

Страница 15: ...r example 1234 7 5 0 1 2 17 Set Indicator Press administrator password 7 6 0 1 0 off 1 on For example 1234 7 6 0 1 18 Set Door Sensor Mode Press administrator password 7 4 0 1 0 NC 1 NO For example 12...

Страница 16: ...e times and no operation is performed 1 minute later the number of pressing a key by mistake allowed is resumed to five times 23 Restore Default Settings You can restore the default settings of the ac...

Страница 17: ...rrect 3 Check whether the access control device is in the correct mode Failed to read the card 1 Check whether the card category is correct or whether the card is damaged 2 Check whether the external...

Страница 18: ...ZKTeco Industrial Park No 32 188 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved...

Отзывы: