background image

Dual Loop Detector LD0l 

User Manual 

 

 

 

 

Configuration

 

 

 

6.1 

LD01 Detector  Connector

 

 

PIN 

DESIGNATION 

 

Live 

12-24V input 

 

 

7

 

Channel 

loop  Twist

 

Channel 

loop this pair 

Channel2 

loop Twist 

 

 

 

 

 

 

 

 

 

 

 

 

a  g  e 

14 

Copyright©2020 ZKTECO CO., LTD. AII rights reserved. 

Neutral 

AC/DC 

Channel2 

Common 

No Use 

 

Channel 

Common 

Channel 

N/O 

 

10 

Channel 2 

loop this pair 

11 

Channel2 

N/O 

 

Содержание LD01

Страница 1: ......

Страница 2: ...documents the contract conditions documents shall prevail The contract specific conditions documents shall apply in priority ZKTeco offers no warranty guarantee or representation regarding the comple...

Страница 3: ...tions of the manual The product will be updated from time to time without prior notice The latest operation procedures and relevant documents are available on http www zkteco com lf there is any issue...

Страница 4: ...rocedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhancement of the development a...

Страница 5: ...ken to avoid danger or mistakes The statement or event that warns of something or that serves as a cautionary example Document Conventions Conventions used in this manual are listed below GUI Conventi...

Страница 6: ...UTOMATIC SENSITIVITY BOOST 9 3 4 PRESENCE TIME 9 3 5 RESET SWITCH 9 3 6 INTERNAL LINK SELECTION 1O 4 FRONT PANEL INDICATOR 1O 5 INSTALLATION GUIDE 11 5 1 OPERATIONAL CONSTRAINTS 11 5 2 LOOP AND FEEDER...

Страница 7: ...osure and relay change over contacts at the 11 pin connector at the rear of the enclosure The power LED indicates that the unit has been powered The channel status LED s below indicate that a vehiele...

Страница 8: ......

Страница 9: ...nce In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop In limited presence mode there will be a finite t...

Страница 10: ...ll indicate the mode status of the detector 1 Any Channel output operating in the presence or pulse modes will come on and extinguish when the system is tuned 2 When the AB Logic mode is selected the...

Страница 11: ...between loops should be adhered to 3 Careful screening of feeder cables if they are routed together with other electric cables The screen must be earthed at the detector end only Reinforcing The exis...

Страница 12: ...rs to reduce the chance of damage that can be caused to the loop at right angle corners NOMINAL SLOTWIDTH 4mm NOMINAL SLOT DEPTH 30mm TO 50mm A slot must also be cut from the loop circumference at one...

Страница 13: ...oopCable 14L 300mm 2M Road Wldlb 300 nm 1 l l4 f 4 SAWCUTS CUR9 l WJ EDGE i 45 OROSSCIR TO PltOYllE STRESS RELEF Figure 5 1 Adj a c ent loops conne cted to different detector modules SURFACE Figure 5...

Страница 14: ...SIGNATION 1 Live 12 24V input 7 Channel 1 loop Twist 8 Channel 1 loop this pair 9 Channel2 loop Twist P a g e l 14 Copyright 2020 ZKTECO CO LTD AII rights reserved 2 Neutral AC DC 3 Channel2 Common 4...

Страница 15: ...ZKTeco Industrial Park No 26 188 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2020 ZKTECO CO LTD AII Rights Reserved...

Отзывы: