6.

Lock

 

Connection

5.DIP

 

Switch Settings

1) Switches1-6  are used to set the control panel number in RS485 communication: It is adopted binary coding and

address number should not be  repeated in the network. 

2) Number 7 switch is used to restore factory defaults: Switch it three times within 10 seconds and restart the device, 

3) Number 8 switch is used to set terminal resistance in RS485  communication: Switch  it to“ON” status, for  adding

4) When electrical lock is connected with access control system, you need to parallel a Fr107

 

diode (equipped in the

1) The control panel provides lock control output interfaces. For NO lock, it is normal open when power is on, so 

2) The control panel supports “dry mode” and “wet mode” by  using the jumper. For  “wet mode”, short 2-3 and 

3) For the Wiegand reader and the InBio reader, the standard power supply is 12V/3A. So we do not  recommend 

 little endian, the address number 

 these 6 switches are shown in the  figure below. Before setting 

is set by placing 

For example: 

Set the

 

device number as 39 (39=1+2+4+32), the switches status are 111001, that is set number 1, 2, 

COM and NO terminals should be used. For NC lock, it is normal

 

closed when power is on, so COM and NC 

 

package) to prevent the self-inductance EMF affecting  the system, do not reverse

 

the polarities.   

 a terminal resistance of 120 ohm between 485+ and 485-.

then all data will be cleared and the system restored to factory default setting.

the address, please keep the system powered off. Place the corresponding  switches to the desired status,

 

and the  

3 and 6 switches at “ON”.

1

2

4

8

16

32

Restore

 

Factory Settings

RS485

 

Terminal

 

Resistance

  EXT

RS485

   PC

RS485

STATE

PWR

READER2

READER1

SWITCH

OUT

ACT

 1   2   3   4

O

 5   6   7   8

N

terminals should be used.

 4-5

 

terminals. The control panel and the lock use separate power supplies: One is connected with +12V and 

 GND of  POWER interface (for the control panel), the other is connected with V+ and V- of LOCK interface

  (for the lock). For  detailed settings for “dry mode” and “wet mode” ,

 

please refer to the Installation Guide.

 The factory default is dry mode. 

3

ACT

D

AUX Input1

E

RS485 

Reader

State  Indicator

D

Exit Button for

 Lock 1

B

Reader for

 Lock 1

B

Reader for

 Lock 1

PC Network

 Interface

Dip switch

RS485 

Converter

PC

D

AUX Output1

C

Lock 1

A Lock Power Input

A

Power Input

LINK

  E
X

T

R

S

4

8

5

   P

C

R

S

4

8

5

S

TAT

E

PWR

R

E

A

D

E

R

2

R

E

A

D

E

R

1

S

W
IT

C

H

O

U

T

ACT

 that the lock and the control panel share a  common power supply. If it is necessary to do, so we suggest using a 
 larger one such as 12V/5A.Not including the power reserved, there are 2A current for the lock. For the common 

electrical lock (the standby current is 300mA, the max current is 500mA), the maximum connected lock is 4. 

AUX Input 1 connect to the infrared human
 body induction, wireless exit button, windows 
sensor with dry contact (no voltage).
AUX Input 1 connect way is same.

Note:

Output Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 0.5A

1

2

3

4

7

5

6

5

1

AUX Output 1 connect to alarm, door bell and so on;
Port (NO, COM, NC) Electrical Parameters: 
MAX  Voltage: 36V(DC)        MAX Current: 1.25A

Note:

AUX Output 1 connect way is same.

Lock1:

Port (SEN)connect to door sensor single with 
dry contact (no voltage);
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC)       MAX Current: 2A

Note: 

When you select Wet mode,the power is Lock power,
Lock 1 total load don’t more than Lock power Rated
 current (2A).
Lock 1 connect way is same.

2

Lock Power Input Electrical Parameters: 
Rated Voltage: 36V(DC)    Rated Current: 2A
Device Power Input Electrical Parameters: 
Rated Voltage: 12V(DC)    Rated Current: 2A

3

4

Exit button for Lock1 connect to Exit button with dry contact.(no voltage);
Reader 1 connect to WG Reader;
Port (+12V)Output Electrical Parameters: 
Rated Voltage: 12V(DC)      Rated Current: 0.5A
Port (BEEP GLED) Output Electrical Parameters: 
Rated Voltage: 5V(DC)        Raged Current: 0.5mA

SD Card Interface:

Function: 

Backup Access 
Control Logs