12 CMP-100A User Manual
(6) Open the cover of the chassis and check whether
parts of the crank-connecting rod mechanism are
stuck or whether lack of solder exists.
Yes
Replace damaged spare
parts or reweld the spare
parts.
(7) Open the door or cover of the chassis and run the
barrier gate to check whether the reducer is stuck or
is idling.
Yes
Replace the transformer.
Abnormal noise is
heard from the
chassis.
Check whether the bearing and the active
connection part are abnormal.
Yes
Lubricate the bearing
and active connection
part or replace the
bearing.
The gate bar does
not fall onto the
specified position.
Check whether the travel switch is properly adjusted
and whether the travel flange is loose.
Yes
Adjust the position of the
travel controller and
fasten the travel flange.
The gate bar shakes
a lot when it falls
onto the specified
position.
Check whether the balanced spring is too loose or
too tight.
Yes
Adjust the tension of the
spring or replace the
spring.