2.3. Ceiling installation
In case the unit must be installed on the ceiling, the minimum horizontal distance from the unit
to the license plate must be of 5 m and the angle between the unit and the floor must not exceed
30º.
The maximum height where the unit could be installed
(h), can be calculated as
follows:
h=L·tanβ
where for a minimum horizontal distance of 5 m, we get h= 2.9 m.
2.4. Electrical installation and cables needed
Each SmartLPR
®
Access recognition unit must have the following cables:
●
Power cable: 3x1.5mm2 or 3x2.5mm2 section cable (alternating current) or 2x1.5mm2
(direct current).
●
Shielded Network cable: UTP cable, category 5 (ethernet networking).
●
Signal cable: 7-pin shielded cable (if the 2 inputs, one output and Wiegand
communication are required) with a 0.5mm
2
cross-section.
For more information about the power consumption of each unit, please refer to the “Technical Data
Sheets” downloaded at http://downloads.quercus.biz/.
Distance (L
≥5m)
He
igh
t
(h)
Camera angle (β≤30º)
Содержание SmartLPR Access
Страница 21: ...SmartLPR Access User Manual Installation Quercus Technologies 22 ...
Страница 35: ...SmartLPR Access User Manual Configuration Quercus Technologies 36 Configuration ...
Страница 42: ...SmartLPR Access User Manual Advanced Concepts Quercus Technologies 43 Advanced concepts ...
Страница 48: ...SmartLPR Access User Manual Annexes Quercus Technologies 49 Annexes ...
Страница 60: ...SmartLPR Access User Manual Annexes Quercus Technologies 61 R D Director ...
Страница 62: ...SmartLPR Access User Manual Annexes Quercus Technologies 63 ...