Battery charger BC1
D01001-02
7
Protection and Safety
Description Symbol
Test
Condition
Value and/or
Range
Unit
Insulation
-
Mains to Battery side
1250
V
AC
Insulation
-
Mains side to Earth
500
V
DC
Insulation
-
Battery side to Earth
500
V
DC
Leakage current
I
L
Supplied equipment
< 3
mA
Input fuse
F1
Inside the equipment
10 (delayed)
A
Output fuse
F2
Inside the equipment
40
A
Minimum output voltage of operation
(Battery Detector)
-
Equipment turn on
1,3
V/cell
Reverse output polarity
-
At the connection to the
Battery
Protection
provided by
fuse F2
-
Thermal protection of semiconductors
(Temperature of Thermal Alarm)
- Ta=55°C
100
°C
Safety Requirements (Rules)
-
EN60335-1, EN60335-2-29
- -
EMC Requirements (Rules)
-
EN55014-1, EN61000-3-3
EN55014-2, EN61000-4-2
EN61000-4-4, EN61000-4-5
EN61000-4-6, EN61000-4-11
- -