Instructions Manual for 5EVM-D Models
M5EVMD2011I
5EVM-D: Electric Vehicle Home AC Charging Station
© ZIV APLICACIONES Y TECNOLOGÍA, S.L.U. 2020
10
4.3.6
Domestic Charge Measurement
The connector, identical to
connector 6
in Figure 5, is specific to the HOME AC or load
balancing accessory. This functionality allows to adapt the power used during the recharge of
the vehicle to the consumption of the house, allowing an intelligent and efficient charge to avoid
as far as possible the obligation of the user to increase the contracted power of the recharging
point.
See, at the end of this manual, specific information on this functionality and the characteristics
of the accessory supplied with the charger if the model purchased includes it.
4.4
Safety Precautions and Maintenance Operations
When handling the equipment for installation, commissioning or maintenance, keep in mind
that:
1. The installation of the recharging point is subject, in a generic way, to the
compliance of all the safety and occupational risk prevention measures that
the company responsible for the installation of the recharging point has
established for this work environment and the safety standards.
2. Specifically, only qualified personnel should carry out the installation and
handling of the equipment, and the operating environment should be
appropriate for the
5EVM
equipment, ensuring compliance with the
conditions indicated in Point 2.
3. Before manipulating or modifying the connection, remove the power supply.
Handling the equipment while it is connected can be dangerous.
4. Incorrect handling or installation of the equipment can cause damage, both
personal and material. Read this instructions manual carefully before
connecting the equipment. Follow all installation and maintenance
instructions throughout the life of the equipment.
5. Do not use this equipment in charging modes not covered by IEC 61851
standard.
6.
ZIV
is not responsible for any damage to persons, facilities or third parties
resulting from failure to comply with points 1,2 and 3.
The equipment does not require any
maintenance operation
except for the periodic checks
stipulated by the regulations in force.
1. Check the installation according to the inspections required by law.
2. Remove from service any element that is not in perfect condition and could
be dangerous, call a qualified technician.
3. Do not use the equipment if the housing or the connector of the EV is broken
or shows any sign of damage.