
CP-S: E512 – INTERCEPTOR NOT CONNECTED
POSSIBLE CAUSES AND CORRECTIVE ACTIONS
•
1RLQWHUFHSWRULVFRQQHFWHGWRWKH'86
1.
Connect at least one interceptor to complete the system installation.
•
$QLQVWDOODWLRQZLWKRGGQXPEHURILQWHUFHSWRUVDUHQRWFRUUHFWO\FRQQHFWHGWRWKH'86
1.
Connect the interceptor pairs to the DU-S starting at PORT/STBD 1.
2.
Connect the single (centerline mounted) interceptor to the PORT3 connector at the DU-S
(see illustration below).
•
$FRQQHFWHGVHUYRXQLWLVQRWLGHQWL²HGE\WKHV\VWHP
1.
Check that the system units listed in the CP-S under ’System Information’ agrees with the
actually connected units.
2.
Check cable and connectors for dirt or damage. Try connecting SU-S to a different connector of
the DU-S. Replace any damaged cables/units.
3.
Verify function of the servo units individually by disconnect all and reconnecting them one-by-one
to DU-S at the PORT3 connector.
4.
Replace any failing servo unit that does not get recognized by the system or otherwise does not
operate
properly.
•
The system cannot identify interceptor or interceptor pairs.
ERROR CODE TRIGGER
9
Installations with a centerline interceptor connected to DU-S PORT 3.
Port interceptor 1 not identified by the system.
Содержание S Series
Страница 1: ...TROUBLE SHOOTING GUIDE...
Страница 12: ......