background image

CP-S ERROR CODES

4

Series S Control Panel (CP-S)

Blt 

Description 

Error message displayed 

Corrective actions 

Error code is cleared when...

code 

 

on control panel

1

 

Low voltage detect 

Supply voltage too low 

• Check battery supply voltage (>12V). 

...supply voltage goes above 9V.

 

 

 

• Check the power cable connection to the battery.

2

 

High voltage detect 

Supply voltage too high 

• Check the distribution unit power cable. 

...supply voltage goes below 32V. 

 

 

 

 

• Check battery supply voltage (12-32V).

4

 

Rotary encoder failure 

Button/wheel failure 

• Check if any buttons or wheels are stuck. 

...power turned on (main switch toggle).

 

 

 

• Use fresh water to spray and remove any dirt on the control panel front. 

8

 

Accelerometer failure 

Acc/gyro error 

• Turn off the sustem for 10 minutes, then restart. 

...power turned on (main switch toggle).

16

 

Gyro failure 

Acc/gyro error 

• Turn off the sustem for 10 minutes, then restart. 

...power turned on (main switch toggle).

32

 

High circuitboard temp 

Panel temp. too high 

• Check if the panel is mounted close to any heat source. 

...circuitboard temperature goes below 75°C.

 

 

 

• Try mounting the panel in another (cooler) location.

64

 

GPS error 

No GPS signal 

• Check GPS source and GPS status on the Select GPS source menu page (norm. set to Auto). 

...GPS signal is acquired (received).

 

 

 

• If an external GPS or NMEA 2000 GPS is installed, check the cables for damage.

 

 

 

• Check the NMEA 2000 GPS source is turned on.

 

 

 

• Clean and reattach the control panel connectors.

128

 

Software exception error 

Program error 

• Restart the system. 

...power turned on (main switch toggle).

 

 

 

• Visit www.zipwake.com for upgrades resolving the issue.

256

 <not 

used>

512

 

Too few interceptors 

Interceptor not connected 

• Check the servo cables for damage. 

...more than one servo unit detected (connected).

 

 

 

• Clean and reattach the connectors on the distribution unit. 

...a single interceptor is detected (connected) at PORT 3.

 

 

 

• Ensure a single interceptor installation is connected to distribution unit PORT 3.

1024

 

CAN-bus error 

Communication error 

• Check the system cables for damage. 

...I-BUS communication is restored.

 

 

 

  - Clean and reattach the connectors on the distribution unit and control panels.

 

 

 

• Identify failing component.

 

 

 

  - Disconnect all interceptors and flybridge control panels.

 

 

 

  - Reconnect units one-by-one to identify which unit triggers error.

 

 

 

     Note: connect the interceptor one-by-one to DU at PORT 3 to avoid triggering error code E512

 

 

 

  - Replace failing unit.

Содержание S Series

Страница 1: ...TROUBLE SHOOTING GUIDE...

Страница 2: ...TROUBEL SHOOTING GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S Release R1A April 2019 Language English Copyright 2019 Zipwake AB Sweden All rights reserved www zipwake com...

Страница 3: ...r individual sets of error codes bit encoded The Distribution Unit DU S do not generate any error codes Presence of system error is indicated in the CP S display by a flashing red info symbol in combi...

Страница 4: ...er cooler location 64 GPS error No GPS signal Check GPS source and GPS status on the Select GPS source menu page norm set to Auto GPS signal is acquired received If an external GPS or NMEA 2000 GPS is...

Страница 5: ...d check that the blades are moving correctly run Interceptor Check 64 Electronics failure Electronics failure Restart the system power turned on main switch toggle Visit www zipwake com for upgrades r...

Страница 6: ...supply issue see previous check list 2 Check if the SU S that reports error operates makes any movement at system turn on 3 Replace SU S if confirmed it is not operating 6HUYR XQLW V VFUHZ VKDIW KDV E...

Страница 7: ...ase of any indication the blades are obstructed Interceptor Check readout not in the green range check for excessive marine growth dirt paint or sealant on interceptor s moving parts 2 Remove the Inte...

Страница 8: ...DFKHG GXULQJ 68 6 VWDUWXS VHTXHQFH 1 Remove any obstacles growth dirt mud paint etc that prevents the interceptor blade to fully retract 2 Check and verify the SU S is mounted with the screw shaft nut...

Страница 9: ...1 Check that the system units listed in the CP S under System Information agrees with the actually connected units 2 Check cable and connectors for dirt or damage Try connecting SU S to a different c...

Страница 10: ...onnect all units in the system except one CP S connected to the DU S on the I BUS OUT connection 2 Connect the SU S units one by one to the DU S at PORT3 connection and identify which SU S that trigge...

Страница 11: ...h designated torque 5 Nm Run the Interceptor Check and verify that the blades are moving freely within tolerance range all the readings of Interceptor Check are in green range Document and archive the...

Страница 12: ......

Отзывы: