SU-S ERROR CODES
5
Blt
Description
Error message displayed
Corrective actions
Error code is cleared when...
code
on control panel
1
High motor temperature
Motor temperature high
• Turn off the system for 10 minutes, then restart.
...motor temp. goes below 81°C.
2
Motor drive failure
Motor HALL sensor failure
• Turn off the system for 10 minutes, then restart.
...power turned on (main switch toggle).
- HALL sensors
4
Motor drive failure
Motor drive failure
• Turn off the system for 10 minutes, then restart.
...power turned on (main switch toggle).
-
Phases
8
Low voltage detected
Supply voltage too low
• Check battery supply voltage (>12V).
...supply voltage goes above 8V.
• Check the power cable connection to the battery.
• Check the distribution unit power cable.
16
Interceptor stroke too small Interceptor stroke too small
• Turn off the sustem for 10 minutes, then restart.
...system is restarted (power button).
32
Interceptor stroke too big Interceptor stroke too big
• Restart the system.
....system is restarted (power button).
• Remove the interceptor front and check that the blades are moving correctly.
Remove any growth, dirt or paint.
• Reinstall the front, run the interceptor and check that the blades are moving correctly
(run Interceptor Check).
64
Electronics failure
Electronics failure
• Restart the system.
...power turned on (main switch toggle).
• Visit www.zipwake.com for upgrades resolving the issue.
128
Emergency stop
Overload, interceptor stuck
• Check that the blades are moving correctly (run Interceptor Check).
....system is restarted (power button).
• Check for excessive growth, dirt, paint or sealent on the interceptor and between the moving
components.
• Remove the interceptor front and check that the blades are moving correctly.
• Verify no components are missing (screws, seal, strip, rollers, slide blocks).
• Verify the back plate is flat within tolerance according to installation guide.
• Reinstall the front (tighten with designated torque), run the interceptor and check that the
blades are moving correctly (run Interceptor Check).
• Verify that the system is not connected to power supply via automatic (thermal/magnetic) fuse.
256
High voltage detected
Supply voltage too high
• Check battery supply voltage (12-32V).
...supply voltage goes below 32V.
512
High circuitboard temp
Motor driv temp. too high
• Turn off the system for 10 minutes, then restart.
...circuitboard temp. goes below 64°C.
1024
Motor over current
Motor over current
• Turn off the system for 10 minutes, then restart.
...system is restarted (power button).