5      5V, 12V, 3.3V, 5Vsb, -12V ( ATX / EPS ) 

6      5V, 12V, 3.3V, 5Vsb, -5V, -12V ( ATX / EPS ) 

 

7th --- # of total wattages 

XXX --- XXX W   

AXX --- 10XX W 

BXX --- 11XX W 

CXX --- 12XX W 

………       

     

8th --- attribute       

X --- P      w/ PFC 

F      w/ EMI filter     

                  V      HIGH EFFICIENCY 

 

9th --- Use FAN type 

X --- 3      use 3.8CM type 

4      use 4CM type 

6      use 6CM type 

8      use 8CM type 

 

10th --- chassis type 

X --- H      horizontal type 

V      vertical type 

M      hori vertical type 

 

Содержание M1S2 series

Страница 1: ...Each power module is designed with 5 outputs 3 3V 5V 12V 12V and 5Vsb circuits and compliant to ATX12V All you can see on the backplane is just passive components and this is the key point for longer...

Страница 2: ...1 2 3 4 5 6 7 8 9 10 1st Category X blank AC input AC DC D 48Vdc input B 24Vdc input 2nd Serial ID X R redundant 1 1 M redundant N 1 3rd for U use Y 1 for 1U use 2 for 2U use 4th PM or Customer speci...

Страница 3: ...tal wattages XXX XXX W AXX 10XX W BXX 11XX W CXX 12XX W 8th attribute X P w PFC F w EMI filter V HIGH EFFICIENCY 9th Use FAN type X 3 use 3 8CM type 4 use 4CM type 6 use 6CM type 8 use 8CM type 10th c...

Страница 4: ...odule Hot swap and hot plug ability Full range 90VAC 264VAC operation Active Power Factor Correction PFC built in Balance load sharing design Remote sensing design Meet FCC CISPR EMI regulation Faulty...

Страница 5: ......

Страница 6: ...AND 3 3V NOT EXCEED 170W 2 POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 400W 500W C SPECIFICATION TEMPERATURE RANGE OPERATING 0 40 STORAGE 20 80 HOLD UP TIME 16mS MIN AT FULL LOAD 115 VAC INPUT VOLTAGE...

Страница 7: ...your system chassis then please power it on If the power system operates normally the individual LEDs on power module and the external warning LED light in GREEN Now remove one power module from the...

Страница 8: ...been burned This is due to the cover of the power module is used as heat sink for cooling Usually its temperature is around 50 60 degree Celsius under full load condition 2 Loose the screws of power...

Страница 9: ...to test this new power module and simulate the defective situation please refer to Section 1 7 Installation Testing Remarks If the DC fan of the power module fails you have to replace the power module...

Страница 10: ...ule inserted SINGLE MODE and REDUNDENT MODE 1 SINGLE MODE only one module inserted and power on Notice items a When only one module inserted the detect circuit will assume the other empty module is Du...

Страница 11: ...correct if any connection loosed if the direction is incorrect etc 2 Check if any short circuit or defective peripherals by plugging out the power connector from each peripheral one at a time Shall t...

Страница 12: ...Note The description stated herein is subject to change without prior notice All brand names and trademarks are the property of their respective owners...