ASSEMBLY
Z.I.P.P.E.R Maschinen Austria
www.Zipper-maschinen.at
Seite24
Rolltischsäge / Roll table saw ZI-RTS700
13.4
Mounting
The rolling table saw is supplied pre-assembled.
As described in 8.1, loosen table backup on both sides
(Fig. C)
.
13.5
Electrical connection
A T T E N T I O N
When working on an ungrounded machine:
Serious injury due to electric shock in the event of a malfunction possible!
Therefore: appliance must be grounded and operated on a grounded outlet can be
The electrical connection of the machine is ready for operation on a grounded outlet!
If a plug is supplied, this must only be connected to a properly fitted and grounded electrical out-
let!
The plug (if supplied) must not be changed. If this does not fit or is defective, only a qualified
electrical engineer may modify or replace the plug!
The grounding conductor is green-yellow!
In the event of repair or replacement of the grounding conductor must not be connected to an
under voltage can!
Check with a qualified electrician or service that the grounding instructions are understood and
the machine is grounded!
A damaged cable must be replaced immediately!
13.6
Pre-commissioning work
All covers and safety devices must be correctly installed and the saw blade must be able to run
freely.
Check the direction of the saw blade by the machine very briefly on and off. The saw blade
must rotate from the left side as viewed clockwise. ( see direction arrow on the saw blade ) If
this is not the case, the direction of rotation must be corrected by means of the phase inverter
on the connector.
For this purpose, using a screwdriver phase inverter in the connector 180 ° turn ( see Fig. B ).
Right direction: see arrow on the blade guard.
Make sure that the blade is stuck, is in perfect condition, is sharpened and guarantees perfect
operation.
When cut for foreign objects , such as wires , nails, etc. - as well as irregularities in the mate-
rial such as knots.
Verify that the moving parts are working properly and not jam.