CLEANING, MAINTENANCE, STORAGE, DISPOSAL
31
ZI-STE1000INV
14.2.1
Maintenance plan
The type and degree of machine wear depends to a large extent on the operating conditions. The
following intervals apply when the machine is used within the technical limits:
(1) Interval can vary according to
the air quality
(2) Only by specialists!
Prior to
each
start
(for new
machine)
after first
Month or
20 opera-
tion hours
Every 3
months
or every
50 opera-
tion
hours
Every 6
months
or every
100 oper-
ation
hours
Every 12
months
or every
300 oper-
ation
hours
Every 2
years
Engine oil
Control the level
X
Change
X
X
Air filter
Control
X
Change
X (1)
Spark plug
Control
X
Change
X
Spark arrester
Clean
X
Fuel tank and
fuel filter
Control
X
Change
X (2)
Fuel pipe
Control
X (2)
14.2.2
Changing the engine oil
N OTE
Waste oils are toxic and must not be released into the environment!
Contact your local authorities for information on proper disposal.
Drain the used engine oil while it is still warm from operating the machine (drains easier).
•
Loosen the screw (1) and remove the cover (2).
•
Unscrew the dipstick (3) from the oil filler opening (4).
•
Drain the old oil into a suitable container.
•
Fill in new engine oil and check the engine oil level with the
dipstick (3) (regarding engine oil type and oil tank capacity
see technical data).
•
If the oil level is correct, reinsert the dipstick (3).
•
Remove oil residues with a cloth.
•
Screw the cover (2) back on.
•
Place the machine on an even surface and start the engine.
If there is sufficient engine oil filled in, the low oil alarm will
be not activated.