OPERATION
27
ZI-STE1000INV
13.2.2
Checking the fuel tank level
N OTE
Observe the safety regulations for fuel control.
Filter the fuel during refuelling to prevent
foreign particles from entering the combustion chamber. Wipe up leaked fuel.
WARNIN G
Never refuel if the engine is running
•
Place the machine on a firm and flat surface.
•
Open the fuel filler cap (1).
NOTE:
Never refuel without filtering the fuel!
•
Refuel with unleaded fuel until the max. filling
level indicator is reached (2).
•
Close the fuel filler cap (1) tightly after refuelling.
13.2.3
Grounding
The machine is designed with the protective measure protective separation with potential equaliza-
tion in the IT network. A grounding by means of a grounding screw and a grounding spike is thus
designed to discharge static charges. For this purpose, connect the grounding screw of the power
generator to a grounding spike (grounding cable cross-section 16mm²). If other protective measures
are required, clarify them with a qualified electrician and have them documented in order to check
their effectiveness.
13.3
Information on Initial Start-up
13.3.1
Test Run Initial Start-up
Make sure to treat the machine with care, when using it for the first time.
•
Let the machine run idle for about 3 minutes before connecting the generator with consumer
load.
•
Pay attention to abnormal noises.
•
Pay attention to the exhaust fumes (too black, too white)?
If these points meet the demands, the machine can be used further. Otherwise stop the machine and
find the cause of the problem.
13.4
Switching on the machine by an electrical amateur
Switching on without a qualified electrician, the following requirements must be met:
•
The machine is checked at regular intervals by a qualified electrician (recommended every six
months).
•
Extension and connection cables as a well as plugs/sockets must be checked regularly for
mechanical damage.
•
Only use cables and conductors that are permanently suitable for the intended use.