807042 v1.00 03.21 HydroTap G5 UltraCare Install Instruct

WARNINGS AND PRECAUTIONS

Safety

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by 
a person responsible for their safety. For products sold in Europe, this appliance can 
be used by children aged from 8 years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. Children should be supervised to ensure that they 
do not play with the appliance. Cleaning and user maintenance shall not be made by 
children without supervision.

Refrigerant

HydroTap chilled models contain R134A refrigerant under pressure. Maintenance 
of the refrigeration unit must be carried out by an accredited service provider or 
qualified refrigeration technician.

Qualifications

If the power cable is damaged it must be replaced by a qualified technician. To 
avoid hazards, all installation procedures must be carried out by a suitably qualified 
tradesperson. 

Venting

Occasionally steam and / or boiling water may discharge through a vent outlet on the 
tap. Ensure the tap body is located so the tap outlet safely dispenses into the drip tray 
or sink bowl area.

Lifting

Take care when lifting. The Command Centre may exceed safe lifting limits. If you feel 
this is beyond your personal capabilities, please seek assistance with the lift. Do not 
lift the Command Centre by the front cover or any of its connections. Refer to the 
technical specification for the weight of the product.

Airflow

The ambient operating temperatures, when installed in a cupboard, must be between 
5°C - 35°C. The system will operate satisfactorily only if the recommended air gaps of 
50 mm on each side, and 200mm above the Command Centre are provided. If a vent 
kit is supplied it must be fitted.

Frost Protection

If this appliance is located where the ambient air temperature could fall below 5°C 
when the heater is not in use, do not turn off the appliance electrically. This safeguard 
does not offer the same protection to the connecting pipework and fittings.

15.  For water taste and quality reasons, following any non-use period of 

more than 72 hours, Zip recommends to perform a system flush. Failure 

to flush the system may affect water quality.

Содержание UltraCare BCU40

Страница 1: ...1 807042 v1 00 03 21 HydroTap G5 UltraCare Install Instruct Model UltraCare BCU40 Installation Instructions Zip HydroTap G5 PRODUCTLABEL Visit our website to download the manuals Australia...

Страница 2: ...19 Cleaning 19 End of life disposal 19 Thank you for choosing Zip HydroTap Enjoy filtered boiling and chilled water from the Zip HydroTap The HydroTap Command Centre installed under the bench has a co...

Страница 3: ...ple portable socket outlets or portable power supplies at the rear of the appliance 8 Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the po...

Страница 4: ...technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson Venting Occasionally steam and or boiling water may discharge through a vent outlet on...

Страница 5: ...ses Classic tap shown part no 91519 BC chrome 1 x HydroTap Command Centre including water filter cartridge 1 x mains water braided hose part no 90056 Side Duct part no 91505 Vent Kit BC Model 1 x Inle...

Страница 6: ...ving jurisdiction The system is only designed to reduce normally occurring non pathogenic nuisance microorganisms Class B systems are not intended for treatment of contaminated water UltraCare BCU40 C...

Страница 7: ...are required The appliance must be connected to a potable water supply with min max working pressure as outlined in the Technical specifications with isolating valve within reach of the hose and posit...

Страница 8: ...Tap Command Centre Mains power supply to Command Centre Power for UV C Module Vent tray Side duct Mains water inlet isolation valve not supplied Step 1 Positioning Ensure there is adequate space in th...

Страница 9: ...out in cabinet oor Inlet vent options Fit the silicone door buffers to the inside edge of the cupboard door to provide an air space Step 2 Ventilation IMPORTANT Allow a minimum clearance envelope of...

Страница 10: ...ted with a drain 3 1 Pass the hoses down through the hole and locate the tap in place 3 4 From below the benchtop push the washer over the hoses and threaded rod then push the spider clamp onto the th...

Страница 11: ...Flush water supply lines before any plumbing connections are made to prevent sediment from affecting operation Connect electrical cable to the side of the Command Centre Power must remain OFF until co...

Страница 12: ...UE hose from tap Push at least 15mm over the fitting Connect USB C cable from UV C Module to HydroTap Ensure hose has constant fall Connect 12V power supply to HydroTap Power must remain OFF until com...

Страница 13: ...ection Push the hose over the connector for a minimum of 15mm There a constant fall from the tap down to the Command Centre Hoses must be trimmed to avoid loops and kinks Take care when positioning be...

Страница 14: ...filter factory setting With external filter Set bypass valve optional The bypass valve diverts the boiling feed water to external filtration optional internal filter is supplied with the unit The valv...

Страница 15: ...urn electrical power ON at both the power outlets 6 2 Step 6 Commissioning 10L bucket not supplied Open valve to let water flow Close valve when complete Do not commission your HydroTap until it is re...

Страница 16: ...ch requires the product to be flushed with fresh water at installation as shown on the Command Centre screen Each tank boiling and chilled must be emptied and filled three times For countertop font in...

Страница 17: ...p Service Cold sensor Closed Internal fault Call Zip Service Flood sensor Open Internal fault Call Zip Service Condenser sensor Closed Internal fault Check Ventilation Call Zip Service Condenser senso...

Страница 18: ...ools down and reports that its internal temperature has returned to 40 C or lower UV Under Current Tried to dispense cold water and current of UV C Module not at minimum threshold a The 12V external p...

Страница 19: ...help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details End of life disposal In Australia Zip offers a full...

Страница 20: ...efer to User Guide for operation and maintenance ZipWater Australia PtyLtd ABN46000578727 67 77AllinghamStreet CondellParkNSW2200 Postal LockedBag80 Bankstown1885 Australia Tel 612 97963100 Freecall18...

Отзывы: