05
806393 v1.08 09.19 Micro Install Instructions
the appliance in a safe way and understand the hazards involved. Children should
be supervised to ensure that they do not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Refrigerant (BC model)
The HydroTap Micro (BC model) contains R134A refrigerant under pressure.
Maintenance of the refrigeration unit must be carried out by an accredited service
provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be replaced by a qualified technician. To
avoid hazards, all installation procedures must be carried out by a suitably qualified
tradesperson.
Venting
Occasionally steam and / or boiling water may discharge through a vent outlet on
the tap. Ensure the tap body is located so the tap outlet safely dispenses into the
drip tray or sink bowl area.
Lifting
Take care when lifting. The Micro command centre may exceed safe lifting limits. If
you feel this is beyond your personal capabilities, please seek assistance with the lift.
Do not lift the Micro command centre by the front cover or any of its connections.
Refer to the Technical specification for the weight of the product.
Airflow
The ambient operating temperatures, when installed in a cupboard, must be
between 5°C - 35°C. The system will operate satisfactorily only if the recommended
air gaps of 50 mm on each side, and 200mm above the command centre are
provided. If a vent kit is supplied, it is recommended to be fitted according to these
instructions.
Frost Protection
If this appliance is located where the ambient air temperature could fall below
5°C when the heater is not in use, do not turn off the appliance electrically. This
safeguard does not offer the same protection to the connecting pipework and
fittings.
WARNINGS AND PRECAUTIONS