background image

806835 v1.02 05.21 G5 User guide

8

 SECTION 2: Using the HydroTap

2.2 Touch-Free Wave 

Touch-free

Controls 

Touch-free 

sensors on the tap top, 
back and sides.

Touch-free

Lights

Dispense  

sensors

Safety  

sensor 

 (at back)

Light

Touch-free

Touch-free

Clearance requirements

100mm

100mm

100mm

100mm

RED

 Boiling & safety 

sensors activated, water 
dispensed. 

BLUE

 Chilled sensor  

activated, water dispensed. 

WHITE

 Sparkling sensor 

activated, water dispensed.

PURPLE 

 Lock mode on (when tap is idle). 

Flashing RED

 Sensor activated incorrectly; hand 

may be too close to sensor, sensor has been 
touched or covered. 

WHITE / BLUE / RED Cycling 5 to 10 seconds

Filter needs replacing, CO2 warning (G5), unit 
is in an error mode (refer to Command Centre 
screen).

WHITE Flashing rapidly 

Sensors calibrating when 

power is first applied to the tap. Allow 10 seconds.

Содержание HydroTap G5 BA60

Страница 1: ...806835 v1 02 05 21 G5 User guide 1 UserGuide HydroTap G5 Visit our website to download the manuals Australia UK...

Страница 2: ...806835 v1 02 05 21 G5 User guide 2...

Страница 3: ...1 Filter settings 19 3 5 2 Temperature settings 22 3 5 3 CO2 settings 24 3 5 4 Dispense times 26 3 5 5 Light sensor 26 3 5 6 Quiet mode 27 3 5 7 Advanced settings 1 27 3 5 8 Advanced settings 2 Wave T...

Страница 4: ...806835 v1 02 05 21 G5 User guide 4 Navigate to the register product menu Scan the QR code and follow the on screen steps to register your product Register product...

Страница 5: ...c shock Hot surface SECTION 1 SAFETY 1 2 Before you start Read the WARNINGS and PRECAUTIONS Download read the complete Command Centre installation instruction manual and user guide Read and use the in...

Страница 6: ...6 SECTION 2 Using the HydroTap SAFETY BOILING CHILLED CHANGE FILTER SAFETY Touch free Classic Arc Cube and Celsius HydroTap Mixer Taps Touch Free Wave Classic Plus Elite Plus See page 6 See page 7 Se...

Страница 7: ...lled Sparkling Boiling ON Ready to dispense FLASHING SLOWLY Water temperature not at set point FLASHING QUICKLY System fault Simply press to dispense chosen water type Safety lock Safety lock Info ON...

Страница 8: ...ensors activated water dispensed BLUE Chilled sensor activated water dispensed WHITE Sparkling sensor activated water dispensed PURPLE Lock mode on when tap is idle Flashing RED Sensor activated incor...

Страница 9: ...s Sensor range 1 4cm To dispense hold hand within range of the sensors Tap will not operate and light will flash if the sensors are touched or if your hand is too close Boiling Water Chilled Ambient S...

Страница 10: ...ct touch to select water type SAFETY SAFETY SAFETY SAFETY LOCK ON Lights Indicator Select Safety SAFETY ON Ready to dispense ALL LIGHTS FLASH CONTINUOUSLY System fault refer to Command Centre LCD Hydr...

Страница 11: ...spense Lights BOILING CHILLED CHANGE FILTER SAFETY Dispense options Boiling ready Chilled sparkling ready Filter Use boiling chilled sparkling or ambient lever to dispense your water choice SAFETY SAF...

Страница 12: ...806835 v1 02 05 21 G5 User guide 12 SECTION 2 Using the HydroTap 2 5 HydroTap Mixer taps Controls mixed water Hot Cold Lift and rotate the lever to dispense mixed warm water...

Страница 13: ...reen Here s an example Set the language from the home screen Touch the top left icon to navigate to the main menu Then touch the general settings icon to navigate to the general settings menu MAIN MEN...

Страница 14: ...d Centre ON or OFF The LCD screen visually shows OFF when it is non operational You will hear the sound of an internal click as the HydroTap Command Centre turns ON or OFF When OFF all functions are d...

Страница 15: ...lled models CO2 gas remaining Sparkling models 12 12 PM 0 CO2 GAS REMAINING REPLACE CO2 GAS When the CO2 cylinder has approximately 20 remaining a warning appears to encourage you to prepare a replace...

Страница 16: ...21 G5 User guide 16 SECTION 3 Command Centre Screen 3 3 Main menu Use the Main menu to configure your HydroTap and access features and settings Touch each icon to access further options 3 4 General se...

Страница 17: ...7 SECTION 3 Command Centre Screen Date and time Touch the text boxes on the screen and then press and to set the current date and time Press the tick to confirm and save Network Connect to Wi Fi avail...

Страница 18: ...806835 v1 02 05 21 G5 User guide 18 3 5 System settings Configure your HydroTap to suit your needs Navigate to system settings screen for all system settings SECTION 3 Command Centre Screen...

Страница 19: ...ing of a new installation and after every filter change See page 35 for filter change instructions 3 5 1 Filter settings FILTER SETTINGS 12 12 PM Filter Reset Filter Life Filter Flush Tank Flush Open...

Страница 20: ...w being flushed through the filter This process is automatic and will take 2 minutes Press pause to pause filter flush Approximately 10L of water will flow for 2 minutes The screen will show the filte...

Страница 21: ...internal external filter and edit the filter life months or litres and actual usage days or litres When usage exceeds the filter life the tap lights and screen will indicate to change the water filter...

Страница 22: ...igher temperature setting Up to 6 less energy in standby is consumed with a 98 C set point rather than 100 C A warning icon will appear when setting boiling set point temperatures that are subject to...

Страница 23: ...from the tap spout On start up the HydroTap self calibrates or go to this menu to recalibrate Calibration will take around 10 minutes External Booster For selected commercial Boiling models an extern...

Страница 24: ...pes from the tap The purge process stops automatically 3 5 3 CO2 settings 12 12 PM PURGE WATER WITH CO2 INFO This process removes water from the sparkling chamber when a new CO2 bottle is installed Th...

Страница 25: ...o grams absorbed Months of use may also be selected to trigger a reminder to prepare a replacement CO2 cylinder Usage is dependent on CO2 absorption settings on the HydroTap and leak free installation...

Страница 26: ...room is typical for operating conditions The lights on the tap will flash to confirm calibration When the room is darkened below the calibrated light level the tap lights will turn OFF after 30 secon...

Страница 27: ...se Power Pulsing Mode Hot setpoint must be 98 5 C to disable Periodic Pulse Reduced Cavitation Mode Sends two electric pulses every 5 minutes to the pump This prevents the build up of air bubbles insi...

Страница 28: ...kling Wave Tap Sensor Demister Mode Enabled default activates the Wave Tap internal heater to prevent its sensors from being affected by condensation from steam Disabled choose this option to conserve...

Страница 29: ...ety button to dispense hot water Hot isolation additional boiling safety 3 slow safety button presses required prior to dispensing Boiling safety lock Enabled default safety button must be touched tap...

Страница 30: ...protect Activate passcode protection to limit access to certain settings Users will be prompted for this passcode when attempting to access settings Create a 4 digit passcode and re enter as prompted...

Страница 31: ...bled default Enabled Any attempt to dispense water will bring the HydroTap out of sleep mode Allow sufficient time for the water to reach the set temperature Sleep when Select from It gets dark Not us...

Страница 32: ...ghted When OFF the HydroTap will stop chilling and heating the drinking water During OFF mode any attempt to dispense water will bring the HydroTap back ON Allow sufficient time for the water to reach...

Страница 33: ...et 3 7 3 Energy Use Track energy usage of your HydroTap by viewing the total energy consumed and the energy consumed since the last energy use reset 12 12 PM SET TIMER Off at On at Mon Tue Wed Thu Fri...

Страница 34: ...cent Faults ABOUT SYSTEM 12 12 PM Title Info Module App revision Serial No Product No Calibration 50L Filtered Wi Fi MAC Address BCS100 017 H5v0 1 xx 0000000000000 H500xx000AU N A N A BS 0 00 FW 0 00...

Страница 35: ...he filter may require changing before the filter change indication is shown You may also need to replace the filter if you notice an increase in chlorine taste or odour Place a cloth or towel under th...

Страница 36: ...ge 19 Clean up and dispose of old cartridge and packaging If the HydroTap is switched off for a long period of time e g more than a weekend run water through the chilled water outlet for at least 60 s...

Страница 37: ...tenance 4 2 Air inlet filter maintenance Remove and clean quarterly Rinse off with tap water Gently dry with a cloth or towel Maintain at least a 50mm air gap in front of the air inlet screen at all t...

Страница 38: ...y immediately with a clean dry cloth Do not use strong corrosive spray or abrasive cleaners Command Centres must never be located near or cleaned with water jets For the Touch Free Wave Tap Do not use...

Страница 39: ...I I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I I I IIII...

Страница 40: ...I I I I IIIIIIIII I I I I I I I Cylinder pressure Outlet pressure Regulator control knob Cylinder connection Gas hose connection Set to 3 0 bar SECTION 4 User maintenance Universal G5 CO2 regulator 1...

Страница 41: ...IIIIIIIII I I I I I I I I I I I I I I I I Replace cylinder and refit regulator I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I...

Страница 42: ...I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I...

Страница 43: ...strap Unscrew regulator connection Replace cylinder and refit regulator Strap in place Turn ON regulator valve Test for leaks in these areas Test for leaks by brushing with soapy water and looking for...

Страница 44: ...77 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia 612 9796 3100 Free Call Aust 1800 947 827 www zipwater com Zip Water UK Trafalgar House Rash s Green Dereham Nor...