Page 20 of 32
801910 v3.05 09.20 HT BCS Commercial Instructions
Booster Specifications:
Rating Unit
Nominal Power Rating
2.2
kW
Nominal Current
10
A
Electric Supply 50Hz AC
230
V
Elect flex and plug - 1 meter length (with 90º Australian plug)
10
A
Fixed Flow Rate
1.2
L/min
Minimum water pressure
200
kPa
Section 4
Booster Heater
(240 models)
Mount base
horizontally
4.1
Product Description
The boost unit is a compact electronically
controlled auxiliary water heater. It is intended to
provide pre heating of water before it enters the
Zip HydroTap G4 boiling tank. The Booster is
supplied as standard equipment with all 240 cup
models. However, it may be later installed, as an
accessory for the 160 cup models, to increase
their delivery to 240 cups.
400mm
Note 1:
water connection
Blue marking - water in
Red marking - water out.
The braided hoses cannot be
lengthened.
Note 2:
The electrical cable
length is 1.0 metre.
Note 3:
Position the Booster
within reach of the fixed hose
lengths, keeping the Booster
as close as possible to the
Command Centre inlet/ outlet
fittings.
Note 4:
Ensure the Booster
heater is mounted in an up-
right position (as shown) with
a horizontal base