background image

Zip Hydro Tap Installation and Operating Instructions - 81467 - April 2006

Page 5 of 20

In addition to normal tools, the following will be required:

35mm diameter sheet metal hole punch for sink tops. (not supplied)

35mm diameter hole saw for timber bench tops. (not supplied)

Nut runner tube spanner (supplied) for fixing tap assembly.

When installing a Font unit:

108mm diameter sheet metal or hole saw to suit surface being cut.

Special tools required

Step A - Installing the tap 

1. Make sure that the tap location will allow the nozzle to drain into the sink.

2. Install the 35mm hole in the bench / sink top.

3.

Ensure the black plastic spacer remains in place as this is the moisture

seal against the bench / sink top.

A light smearing of silicon sealant on

the underside of the spacer will ensure a watertight fit.

4. Pass all three hoses through the 35mm hole and carefully locate the Head

Assembly and black spacer on the bench / sink area.

5. From the underside of the bench / sink area install the S/S washer and

“Spider Clamp” by feeding each of the three tubes and electrical cable
evenly in between the legs of the “Spider Clamp”. Slide it up to meet the
“All Thread”, and pass the “All Thread” through the center of the “Spider
Clamp”.

6. Hold the “All Thread” steady and fit the 6mm nut to the “All Thread” using

the tube spanner supplied in the kit. Check the Tap Head position before
securing it tightly against the bench / sink top.

NOTE 1: The tap assembly must not be positioned more than 900mm 

above the base of the HydroTap unit.

Failure to do this may result in poor water delivery.

NOTE 2: Under no circumstances should the Tap be twisted after the

installation is complete.

Installation procedure

This switch must provide all-pole disconnection and a contact separation
of at least 3mm installed in accordance with wiring rules.

Cold water supply with a minimum working pressure of 70 kPa and a
maximum working pressure of 700 kPa connected via an isolation valve. If
pressure is likely to exceed 700 kPa, install a 500 kPa Pressure Limiting
Valve.

The fitting of an air flow vent cut into the top half of the cupboard door
concealing the HydroTap requiring a cut size of approximately 100mm
circular, to provide adequate warm air displacement. In installations where
high volume  draw-off will occur, the fitting of the accessory exhaust fan is
essential.

Important:  Do not proceed with the installation if these requirements are
not met.

Installation Requirements 

continued

Black
Plastic
Spacer

See note 3.

Note: 

A stainless steel washer is

supplied to go in between the
Spider Clamp and the underside
of the sink top. See location as
shown.

Spider
Clamp

Fixing nut

S/S

Washer

Tap

All-thread rod

Benchtop

Содержание HydroTap BC 100 Series

Страница 1: ...lled drinking water for kitchens and tea rooms Installation and Operating Instructions 81467 April 2006 This Installation Instruction covers the following HydroTap models BC series B series HT series...

Страница 2: ...ommissioning 7 Font Installation procedure 8 Operating the Tap 9 Cleaning 10 Replacing the Filter 10 Pull out Font Template pages a b c d Setting the Energy Saver Timer 11 AuxillIiary Fan Attachment 1...

Страница 3: ...gh usage applications this must be installed in the top half of the cupboard door as a matter of course An accessory exhaust fan kit is available and should be used to ensure adequate ventilation Make...

Страница 4: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the heater via a 10 amp G P O Installation...

Страница 5: ...dy and fit the 6mm nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not b...

Страница 6: ...d connect it to the hot water outlet located on the top center right hand side of the undersink unit Use spring clamps provided Measure and trim the unmarked tube and connect it to the vent outlet loc...

Страница 7: ...he water to 95 C maintaining it at that temperature for a short stabilization period Once stabilized the element will cycle On bring the water to boiling point and hold it there for a short period The...

Страница 8: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re tig...

Страница 9: ...illed water Pulling up the Blue lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position...

Страница 10: ...e and twist right to left one quarter turn until it stops 4 Ease cartridge downwards to detach it from the filter head socket 5 Do not tilt the cartridge as dirty water may spill from it if tilted 6 U...

Страница 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 12: ......

Страница 13: ......

Страница 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 15: ...ed press Adjust button once and Are You Sure will be displayed Press Adjust once and Litres Filtered will be reset to 0 Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mod...

Страница 16: ...th a safety mode that allows protection against accidental operation by Infirmed or disabled persons 1 On the LCD scroll through the menu to Hot Isolation 2 Press adjust to activate 3 Now go to the Ta...

Страница 17: ...k power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check LCD for information Check filter usage on LCD screen if filter change is dis...

Страница 18: ...3 compressor kit BC150 175 7 90633 cold sensor probe kit blue 18 90639 fan motor kit BC100 125 8 90634 pump kit cold 18 90640 fan motor kit BC150 175 9 90622 PCB kit BC100 125 BC150 175 19 90437 capac...

Страница 19: ...ed hose inlet 4 90616 gasket and elbow kit BC 100 125 16 90629 level sensor kit hot tank BC100 125 4 90617 gasket and elbow kit BC 150 175 16 90630 level sensor kit hot tank BC150 175 5 90579 overload...

Страница 20: ...gle Solenoid Kit 4 90658 Gasket and Elbow Kit BC 100 125 5 90579 Overload Kit 6 90618 Element 1500 watt Kit 7 90620 Sensor Probe Hot 8 90621 Pump Kit Hot 9 90689 PCB Kit Boiling Only 10 90624 Leak Sen...

Страница 21: ...Pump Kit Hot 9 90660 PCB Kit Boiling Only 10 90624 Leak Sensor Kit 11 90625 Control Panel Kit 12 90130 Clips Kit 13 90628 Stop Valve and John Guess Fittings Kit 14 90056 Flexible Inlet Hose Kit 15 90...

Страница 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...

Страница 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...

Страница 24: ...nd the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted...

Отзывы: