In addition to normal tools, the following will be required:
•
35mm diameter sheet metal hole punch for sink tops. (not supplied)
•
35mm diameter hole saw for timber bench tops. (not supplied)
•
Nut runner tube spanner (supplied) for fixing tap assembly.
When installing a Font unit:
•
108mm diameter sheet metal or hole saw to suit surface being cut.
Special tools required
Step A - Installing the tap
1. Make sure that the tap location will allow the nozzle to drain into the sink.
2. Install the 35mm hole in the bench / sink top.
3.
Ensure the black plastic spacer remains in place as this is the moisture
seal against the bench / sink top.
A light smearing of silicon sealant on
the underside of the spacer will ensure a watertight fit.
4. Pass all three hoses through the 35mm hole and carefully locate the Head
Assembly and black spacer on the bench / sink area.
5. From the underside of the bench / sink area install the S/S washer and
“Spider Clamp” by feeding each of the three tubes and electrical cable
evenly in between the legs of the “Spider Clamp”. Slide it up to meet the
“All Thread”, and pass the “All Thread” through the center of the “Spider
Clamp”.
6. Hold the “All Thread” steady and fit the 6mm nut to the “All Thread” using
the tube spanner supplied in the kit. Check the Tap Head position before
securing it tightly against the bench / sink top.
NOTE 1: The tap assembly must not be positioned more than 900mm
above the base of the HydroTap unit.
Failure to do this may result in poor water delivery.
NOTE 2: Under no circumstances should the Tap be twisted after the
installation is complete.
Installation procedure
•
This switch must provide all-pole disconnection and a contact separation
of at least 3mm installed in accordance with wiring rules.
•
Cold water supply with a minimum working pressure of 70 kPa and a
maximum working pressure of 700 kPa connected via an isolation valve. If
pressure is likely to exceed 700 kPa, install a 500 kPa Pressure Limiting
Valve.
•
The fitting of an air flow vent cut into the top half of the cupboard door
concealing the HydroTap requiring a cut size of approximately 100mm
circular, to provide adequate warm air displacement. In installations where
high volume draw-off will occur, the fitting of the accessory exhaust fan is
essential.
Important: Do not proceed with the installation if these requirements are
not met.
Installation Requirements
continued
Black
Plastic
Spacer
See note 3.
Note:
A stainless steel washer is
supplied to go in between the
Spider Clamp and the underside
of the sink top. See location as
shown.
Spider
Clamp
Fixing nut
S/S
Washer
Tap
All-thread rod
Benchtop
Содержание HydroTap BC 100 Series
Страница 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Страница 12: ......
Страница 13: ......
Страница 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Страница 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...
Страница 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...