Zip Hydro Tap Installation and Operating Instructions - 81467 - April 2006
Page 3 of 20
Read These Warnings First
Safety
Do not allow young children, handicapped or infirm persons, to use the Zip
HydroTap without supervision.
Refrigerant
The Zip HydroTap Chilling unit contains 134A refrigerant under pressure. No part
of the unit should be exposed to a naked flame. Maintenance of the refrigeration
unit must be carried out by an accredited service provider or qualified
refrigeration mechanic.
Qualifications
If any power cord or plug is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cord and general power outlet must
be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure
the tap body is located so the tap outlet safely drains into the sink bowl area.
NOTE:
On startup, the controls take the system through a calibration process
which causes the unit to over-boil for a period of 90 secs. This is normal
operation, once this mode is completed the system reverts back to normal
operation.
Lifting
Take care when lifting the Zip HydroTap undersink unit. Some units may exceed
safe lifting limits. Do not lift without assistance. The weights of the units are
given in the table under the heading “Installation Requirements”. Do not lift the
unit by the doors.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper
air circulation must be provided. The system will operate satisfactorily only if the
recommended air gaps are provided, these are 65mm min rear clearance and
50mm side clearance. An air vent is provided with each unit for high usage
applications, this must be installed in the top half of the cupboard door as a
matter of course. An accessory exhaust fan kit is available and should be used to
ensure adequate ventilation. Make sure that the ventilation grilles of the
undersink unit are not obstructed.
I
ncluded in the installation pack are adhesive
backed silicon buffers. If air vents are not installed in the cupboards housing the
HydroTap, the buffers must be placed on the inside edge of the cupboard door to
create a slight gap ensuring a minimum airflow. Failure to do this may cause
the HydroTap to overheat and operate inefficiently.
Altitude (not HT boiling only series)
The Zip HydroTap is equipped with a self-calibrating program which caters for
altitude adjustment.
Filter Control (for filtered models)
The Zip HydroTap filter control is preset to 6000 Litres to provide trouble-free
flow and operation in most installations. Local water quality conditions may
require an alteration to this capacity. In areas where the water has a high
concentration of sediment, the preset litre capacity may be shortened to avoid
poor flow, taste or odour situations. In areas where the water quality is above
average, lengthening the preset capacity may be desirable, but not essential. If
any of these changes is needed, follow the instructions on page 11 or contact
your Zip Service Provider.
Zip Hydrotap undersink assembly.
The appliance must be placed in a
horizontal position, as shown above.
The power point must be located within
reach of its cable. The appliance must be
positioned so that the plug is accessable.
Note:
Always ensure the hoses are
shortened so that any excess is
removed and their route is the
most direct line between the tap
assembly and the HydroTap unit.
Do not allow the hoses to sag
or droop so water is trapped
within the hoses. Always
maintain a constant fall
Positioning of the tap assembly
must be within the following
parameters:
The height between the base of
the Hydrotap unit and the base
of the Tap assembly cannot be
greater than 900mm.
Содержание HydroTap BC 100 Series
Страница 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Страница 12: ......
Страница 13: ......
Страница 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Страница 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...
Страница 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...