Zip Hydro Tap Installation and Operating Instructions - 81467 - April 2006

Page 3 of 20

Read These Warnings First

Safety

Do not allow young children, handicapped or infirm persons, to use the Zip
HydroTap without supervision.

Refrigerant

The Zip HydroTap Chilling unit contains 134A refrigerant under pressure. No part
of the unit should be exposed to a naked flame. Maintenance of the refrigeration
unit must be carried out by an accredited service provider or qualified
refrigeration mechanic.

Qualifications

If any power cord or plug is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cord and general power outlet must
be in a safe visible position for connection.

Venting

Sometimes steam and / or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure
the tap body is located so the tap outlet safely drains into the sink bowl area.

NOTE:

On startup, the controls take the system through a calibration process

which causes the unit to over-boil for a period of 90 secs. This is normal
operation, once this mode is completed the system reverts back to normal
operation.

Lifting

Take care when lifting the Zip HydroTap undersink unit. Some units may exceed
safe lifting limits. Do not lift without assistance. The weights of the units are
given in the table under the heading “Installation Requirements”. Do not lift the
unit by the doors.

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper
air circulation must be provided. The system will operate satisfactorily only if the
recommended air gaps are provided, these are 65mm min rear clearance and
50mm side clearance. An air vent is provided with each unit for high usage
applications, this must be installed in the top half of the cupboard door as a
matter of course. An accessory exhaust fan kit is available and should be used to
ensure adequate ventilation. Make sure that the ventilation grilles of the
undersink unit are not obstructed.

I

ncluded in the installation pack are adhesive

backed silicon buffers. If air vents are not installed in the cupboards housing the
HydroTap, the buffers must be placed on the inside edge of the cupboard door to
create a slight gap  ensuring a minimum airflow. Failure to do this may cause
the HydroTap to overheat and operate inefficiently.

Altitude (not HT boiling only series)

The Zip HydroTap is equipped with a self-calibrating program which caters for
altitude adjustment.

Filter Control (for filtered models)

The Zip HydroTap filter control is preset to 6000 Litres to provide trouble-free
flow and operation in most installations. Local water quality conditions may
require an alteration to this capacity. In areas where the water has a high
concentration of sediment, the preset litre capacity may be shortened to avoid
poor flow, taste or odour situations. In areas where the water quality is above
average, lengthening the preset capacity may be desirable, but not essential. If
any of these changes is needed, follow the  instructions on page 11 or contact
your Zip Service Provider.

Zip Hydrotap undersink assembly.

The appliance must be placed in a

horizontal position, as shown above.

The power point must be located within
reach of its cable. The appliance must be
positioned so that the plug is accessable.

Note:

Always ensure the hoses are
shortened so that any excess is
removed and their route is the
most direct line between the tap
assembly and the HydroTap unit.

Do not allow the hoses to sag

or droop so water is trapped
within the hoses. Always
maintain a constant fall

Positioning of the tap assembly
must be within the following
parameters:

The height between the base of
the Hydrotap unit and the base
of the Tap assembly cannot be
greater than 900mm.

Содержание HydroTap BC 100 Series

Страница 1: ...lled drinking water for kitchens and tea rooms Installation and Operating Instructions 81467 April 2006 This Installation Instruction covers the following HydroTap models BC series B series HT series...

Страница 2: ...ommissioning 7 Font Installation procedure 8 Operating the Tap 9 Cleaning 10 Replacing the Filter 10 Pull out Font Template pages a b c d Setting the Energy Saver Timer 11 AuxillIiary Fan Attachment 1...

Страница 3: ...gh usage applications this must be installed in the top half of the cupboard door as a matter of course An accessory exhaust fan kit is available and should be used to ensure adequate ventilation Make...

Страница 4: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the heater via a 10 amp G P O Installation...

Страница 5: ...dy and fit the 6mm nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not b...

Страница 6: ...d connect it to the hot water outlet located on the top center right hand side of the undersink unit Use spring clamps provided Measure and trim the unmarked tube and connect it to the vent outlet loc...

Страница 7: ...he water to 95 C maintaining it at that temperature for a short stabilization period Once stabilized the element will cycle On bring the water to boiling point and hold it there for a short period The...

Страница 8: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re tig...

Страница 9: ...illed water Pulling up the Blue lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position...

Страница 10: ...e and twist right to left one quarter turn until it stops 4 Ease cartridge downwards to detach it from the filter head socket 5 Do not tilt the cartridge as dirty water may spill from it if tilted 6 U...

Страница 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 12: ......

Страница 13: ......

Страница 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 15: ...ed press Adjust button once and Are You Sure will be displayed Press Adjust once and Litres Filtered will be reset to 0 Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mod...

Страница 16: ...th a safety mode that allows protection against accidental operation by Infirmed or disabled persons 1 On the LCD scroll through the menu to Hot Isolation 2 Press adjust to activate 3 Now go to the Ta...

Страница 17: ...k power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check LCD for information Check filter usage on LCD screen if filter change is dis...

Страница 18: ...3 compressor kit BC150 175 7 90633 cold sensor probe kit blue 18 90639 fan motor kit BC100 125 8 90634 pump kit cold 18 90640 fan motor kit BC150 175 9 90622 PCB kit BC100 125 BC150 175 19 90437 capac...

Страница 19: ...ed hose inlet 4 90616 gasket and elbow kit BC 100 125 16 90629 level sensor kit hot tank BC100 125 4 90617 gasket and elbow kit BC 150 175 16 90630 level sensor kit hot tank BC150 175 5 90579 overload...

Страница 20: ...gle Solenoid Kit 4 90658 Gasket and Elbow Kit BC 100 125 5 90579 Overload Kit 6 90618 Element 1500 watt Kit 7 90620 Sensor Probe Hot 8 90621 Pump Kit Hot 9 90689 PCB Kit Boiling Only 10 90624 Leak Sen...

Страница 21: ...Pump Kit Hot 9 90660 PCB Kit Boiling Only 10 90624 Leak Sensor Kit 11 90625 Control Panel Kit 12 90130 Clips Kit 13 90628 Stop Valve and John Guess Fittings Kit 14 90056 Flexible Inlet Hose Kit 15 90...

Страница 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...

Страница 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...

Страница 24: ...nd the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted...

Отзывы: