background image

Zip Hydro Tap Installation and Operating Instructions - 81467 - April 2006

Page 11of 20

Setting the Energy Saver Timer 

(products with this feature only) 

Normal Operation (not available on HT boiling only series)

Set Time 

To change time, press either Mode 

or Mode 

button until Set Time is on the display screen.

Press 

Adjust button to increase time or 

Adjust button to decrease time. Time increases or

decrease in increments of one minute. Hold the Adjust buttons down for rapid increases or
decreases. The time will be displayed in 24Hr mode.

Set Day 

Press either Mode 

or Mode 

button until Set Day is displayed.

Press 

Adjust or 

Adjust to select day.

Filter Life 

( factory set at 6000 Ltrs )

Press either Mode 

or Mode 

button until Filter Life is displayed.

Press 

Adjust button to increase Filter Life or 

Adjust button to decrease Filter Life.

Filter Life increases in 1000 Ltr increments to a maximum of 10000 Ltrs.

Reset Litres Filtered 

This function is to reset the Filter Change display after a filter has reached the end of its life (refer
to “Replace Filter Instructions” section of this document).

Press either Mode 

or Mode 

button until “Litres Filtered” is displayed. Press 

Adjust once and

“Reset Counter” will be displayed, press 

Adjust button once and “Are You Sure” will be

displayed.

Press 

Adjust once and “Litres Filtered” will be reset to 0.

Activating Sleep Mode 

This mode allows the HydroTap to go into Energy Saving mode. In this mode the unit will go to
“sleep” after a pre-determined period of inactivity. Press either Mode 

or Mode 

button until

“Sleep Mode” is displayed. Press 

Adjust once to select 2 Hours or twice to select 4 Hours.

When the period of inactivity passes, the display will show “Sleep Mode”.
During the “Sleep Mode” the Red LED on top of the tap lever will flash slowly.

To de-activate the sleep mode, momentarily operate the Hot lever and then allow sufficient time
for the water to reach the set temperature

Activating On / Off Mode 

Press the Mode 

or Mode 

button until “Monday On” is displayed. To set the time for the unit to

turn on press 

Adjust button until required time is reached.

To set the time for the unit to turn Off press Mode 

button once and “Monday Off” will be

displayed. Now press 

Adjust until required time is reached.

If each individual day is to have an “On / Off” time, these steps need to be repeated for each day
and for each On / Off time.

Note:

The Hydrotap may be temporarily activated during the On / Off Mode. By operating the levers, the
unit will go into normal operation and then remain in an “ON” cycle, until the next “OFF” cycle.

Mode Plus Button

Mode Minus Button

Plus Adjust Button

Minus Adjust Button

Содержание HydroTap BC 100 Series

Страница 1: ...lled drinking water for kitchens and tea rooms Installation and Operating Instructions 81467 April 2006 This Installation Instruction covers the following HydroTap models BC series B series HT series...

Страница 2: ...ommissioning 7 Font Installation procedure 8 Operating the Tap 9 Cleaning 10 Replacing the Filter 10 Pull out Font Template pages a b c d Setting the Energy Saver Timer 11 AuxillIiary Fan Attachment 1...

Страница 3: ...gh usage applications this must be installed in the top half of the cupboard door as a matter of course An accessory exhaust fan kit is available and should be used to ensure adequate ventilation Make...

Страница 4: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the heater via a 10 amp G P O Installation...

Страница 5: ...dy and fit the 6mm nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not b...

Страница 6: ...d connect it to the hot water outlet located on the top center right hand side of the undersink unit Use spring clamps provided Measure and trim the unmarked tube and connect it to the vent outlet loc...

Страница 7: ...he water to 95 C maintaining it at that temperature for a short stabilization period Once stabilized the element will cycle On bring the water to boiling point and hold it there for a short period The...

Страница 8: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re tig...

Страница 9: ...illed water Pulling up the Blue lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position...

Страница 10: ...e and twist right to left one quarter turn until it stops 4 Ease cartridge downwards to detach it from the filter head socket 5 Do not tilt the cartridge as dirty water may spill from it if tilted 6 U...

Страница 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 12: ......

Страница 13: ......

Страница 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Страница 15: ...ed press Adjust button once and Are You Sure will be displayed Press Adjust once and Litres Filtered will be reset to 0 Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mod...

Страница 16: ...th a safety mode that allows protection against accidental operation by Infirmed or disabled persons 1 On the LCD scroll through the menu to Hot Isolation 2 Press adjust to activate 3 Now go to the Ta...

Страница 17: ...k power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check LCD for information Check filter usage on LCD screen if filter change is dis...

Страница 18: ...3 compressor kit BC150 175 7 90633 cold sensor probe kit blue 18 90639 fan motor kit BC100 125 8 90634 pump kit cold 18 90640 fan motor kit BC150 175 9 90622 PCB kit BC100 125 BC150 175 19 90437 capac...

Страница 19: ...ed hose inlet 4 90616 gasket and elbow kit BC 100 125 16 90629 level sensor kit hot tank BC100 125 4 90617 gasket and elbow kit BC 150 175 16 90630 level sensor kit hot tank BC150 175 5 90579 overload...

Страница 20: ...gle Solenoid Kit 4 90658 Gasket and Elbow Kit BC 100 125 5 90579 Overload Kit 6 90618 Element 1500 watt Kit 7 90620 Sensor Probe Hot 8 90621 Pump Kit Hot 9 90689 PCB Kit Boiling Only 10 90624 Leak Sen...

Страница 21: ...Pump Kit Hot 9 90660 PCB Kit Boiling Only 10 90624 Leak Sensor Kit 11 90625 Control Panel Kit 12 90130 Clips Kit 13 90628 Stop Valve and John Guess Fittings Kit 14 90056 Flexible Inlet Hose Kit 15 90...

Страница 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...

Страница 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...

Страница 24: ...nd the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted...

Отзывы: