22
INSTALLATION INSTRUCTIONS & USER MANUAL
T210013 V1.00 FEB 2018 -ZIP HYDROCHILL 20
TECHNICAL SUPPORT
TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
OPERATION
Dispensing operation
• The HydroChill (IT models) is equipped with a volumetric dispensing system.
The dispensing quantities are easily programmable during installation.
• Turn on the HydroChill, the default settings are as follows:
the upper buttons dispense 200 ml of water
the lower buttons dispense 1000 ml of water.
Button functions
• Sparkling water upper dispenser button
(P1)
• Chilled water upper dispenser button
(P3)
• Sparkling water lower dispenser button
(P2)
• Chilled water lower dispenser button
(P4)
• The pre-set quantity of water is dispensed, but you can stop the dispensing
process at any time by pressing the button again.
Setting the quantities
(products with portion control option)
• Using the volumetric dispensing functionality, you can customise the pre-set
quantities dispensed by each of the 4 buttons. Normally, the upper buttons
are used for the dispensing of small quantities, with the lower buttons being
used for the dispensing of larger quantities.
• To enter the programming mode, press and hold (for > 4 seconds) the
following combination of buttons:
(P5)
(see page 23) +
(P3)
+
(P4)
(Energy
saving the two chilled water buttons). When you enter the
programming phase, you will hear three consecutive beeps.
• In this phase, LED
(L1)
+
(L2)
start to flash.
• To set the maximum dispensing limit for a specific button, press the button
in question to start the dispensing process and press it again once you have
reached the desired quantity.
• Repeat the process for the remaining buttons.
• To exit from the programming mode, press and hold (for > 4 seconds) the
following combination of buttons:
(P5)
+
(P3)
+
(P4)
(Energy saving
the two chilled water buttons), save the data and set the new limits.
• The maximum settable quantity for each button is around 3,0 litres, which
equates to a 65-second dispense.