background image

Page 6 of 20 

802701UK - Celsius Comm User Guide - Jan 2016 - V2.02

3

LCD Screen menu

Main  

menu

Sub menu 

Sub menu  

options

Section

Language

English
German

A

 Information

•  Product info. 

 

 

 

 

•  Filters log
•  System faults

•  Module

Revision
Serial number
Product number
Calibration

•  Filters
•  Faults found

B

Installation

•  Filter flush
•  Filter reset
•  Boiling 

calibration

•  Booster
•  Lux sensor 

calibration

•  Start/Stop
•  Internal/External
•  Calibration options
•  Enable/Disable

C

Service

Password 

protected

D

Security

•  Enable 

password

•  Set password
•  Change password

E

Communication 

(Not yet available)

•  Remote monitor
•  Remote control

•  Wifi/Bluetooth 

Options

F

Settings

•  Date/Time
•  Temperature
•  Filter 

•  Energy modes
•  Safety 

 

 

•  Dispense times

•  2hr/24hr Mode
•  Hot/Cold setpoint
•  Filter life (Litres)

Filter life (Months)

•  Sleep mode options 

On/Off modes

•  Safety lock

Hot isolation

•  Hot/Cold  dispensing                

G

Содержание Celsius HydroTap G4 range

Страница 1: ...802701UK Celsius Comm User Guide Jan 2016 V2 02 Page 1 of 20 Affix model number label here 802701UK ZIP HydroTap G4 Celsius User Guide...

Страница 2: ...spring loaded so when released will return automatically close the tap To dispense sparkling water Chilled sparkling model Turn the rotary control clockwise as shown in the adjacent diagram To dispens...

Страница 3: ...on the temperature of the incoming cold water The spout may be swivelled left or right for convenience 3 Tap warning lights Safety Lock Warning light Temperature warning light The warning light will...

Страница 4: ...second off until the fault is rectified See System information page 7 or call Zip on 0845 6 005 005 0345 6 005 005 3 Sleep mode Boiling models In SLEEP MODE the unit will go to sleep after 2 hrs of in...

Страница 5: ...ter External Internal filter needs to be replaced Refer to section C Installation 3LCD Screen Note As an energy saving feature the home screen will turn off after 5 minutes of non use Touching the dar...

Страница 6: ...et Boiling calibration Booster Lux sensor calibration Start Stop Internal External Calibration options Enable Disable C Service Password protected D Security Enable password Set password Change passwo...

Страница 7: ...Faults to check the fault information Press button for the previous menu or press HOME button to return to the home screen Press Filter Log to check the filter resets Press button for the previous me...

Страница 8: ...dge is a flush line approx 600mm long and the flush line stop cock Place the free end of the flush line into the bucket or container not supplied Press MENU button for main menu Press the Install butt...

Страница 9: ...ster unit is installed 4 Booster boiling models 2 Filter reset all models LCD screen operation section C Caution In general boiling water units may vent steam from the tap spout Take care to avoid per...

Страница 10: ...menu Press the Service button A password is required to enter service menu D Service LCD Screen operation Section D 5 Lux sensor calibration all models Press the MENU button for main menu Press the I...

Страница 11: ...ection E To change a password Press the MENU button for main menu Press the Security button Press Change Password Enter your old 4 digit password Then enter your new 4 digit password press Enter Once...

Страница 12: ...the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press NEXT button to set time Set Date Time Press the MENU button for main menu Press the Settin...

Страница 13: ...00 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 17 Filter maintenance Press th...

Страница 14: ...our 4 digit password and press Enter Press the Energy Modes button Press the Sleep Modes button then in the next screen use the up and down arrow to select sleep mode from the 7 options in the table b...

Страница 15: ...at a specific time To activate On Off mode Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off Mode...

Страница 16: ...ion The hot isolation function cannot be used with the Celsius range of taps ensure that this function is disabled Dispense Times all models The ability to change the maximum dispensing time for both...

Страница 17: ...at the top right of the filter and rotate the cartridge a quarter turn clockwise then gently pull down Caution A small amount of water will drip as the cartridge is removed Do not tilt the cartridge a...

Страница 18: ...the condenser The filter screen is a sliding fit in the plastic housing on the left hands side of the Command CentreTM The screen may be removed for cleaning by sliding it forward This needs to be in...

Страница 19: ...button to commence the purging process Wait for the water to stop flowing through the unit Wait a further 10 seconds after the water has stopped running through the tap You will hear the CO2 gas runn...

Страница 20: ...perature The temperature of the water in the Boiling tank will be displayed This is optimises at 98 C but may be adjusted between 68 C 98 C See page 12 for hot set point adjustment Chilled temperature...

Отзывы: