Page 14 of 20
802701UK - Celsius Comm User Guide - Jan 2016 - V2.02
3.
LCD Screen operation - Section G
This mode allows the HydroTap
®
G4 to go into energy saving mode. There
are two options available: sleep mode and on/off mode.
Energy modes
(boiling models)
In sleep mode the unit will go to “Sleep” after a 2hr period of inactivity. The
boiling water will gradually drop to either 68°C or room temp, as shown in the
table below and the chilled water will be ON or OFF.
•
Press the [MENU] button for main
menu.
•
Press the [Settings] button.
•
Enter your 4-digit password and
press [Enter].
•
Press the [Energy Modes] button.
•
Press the [Sleep Modes] button
then in the next screen, use the
up and down arrow to select sleep
mode from the 7 options in the
table below.
It is recommended to recalibrate the lux sensor after selecting any of the lux
sensor options from the sleep mode menu. (See, Lux sensor calibration ,page
10).
Sleep Mode
Light
level
Time
delay
State
Boiler
Chiller
2 Hours > 68
0
C
N/A
2 Hr
Sleep
68
0
C
ON
2 Hours > OFF
N/A
2 Hr
OFF
OFF
OFF
Lux Sensor > 68
0
C
Dark
N/A
Sleep
68
0
C
ON
Lux Sensor > OFF
Dark
N/A
OFF
OFF
OFF
Lux Sensor or 2 Hr > 68
0
C
Dark
2 Hr
Sleep
68
0
C
ON
Lux Sensor or 2 Hr > OFF
Dark
2 Hr
OFF
OFF
OFF
Disable
N/A
N/A
ON
ON
ON
To activate sleep mode
Boiling
Boiling