INSTALLATION INSTRUCTIONS & USER MANUAL 

210005 V2.00 AUG 2017 - ZIP APIII/5-15(OB)

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

•  Before starting installation the WARNINGS   (page 5) and CAUTIONS 

 (page 

6) should be read and fully understood. If in doubt, or in need of further guidance, 
please call Zip Customer Service on 0345 6 005 005

•  Installations must comply fully with UK Water Regulations, Building regulations part G3 

and any Local Authority requirements.

•  The electrical installation including earthing and cross bonding should comply with the 

current IEE regulations and any Local Authority requirements.

•  The Zip Aquapoint III is designed for connection direct to the incoming mains water 

supply and accommodation must be made for the expanded water that will occur 
with each heating cycle. Regulations permit expanded hot water to be accommodated 
within the supply pipe work provided that no check valve, stop valve with loose jumper  
or other fitting can prevent reverse flow. [See diagram 1, (Fig.2) on page 12].

•  Where the expanded water cannot be accommodated in the pipe work and the static 

water supply pressure is under 3.5 bar, fit accessory pack AQ2 (expansion vessel and 
check valve). Where static water pressures are likely to exceed 3.5 bar fit accessory 
pack AQ2 and AQ3 (pressure reducing valve and line strainer).[See diagrams 2&3 
(Fig.2) page 12].

•  If required a temperature and pressure relief valve (accessory AQ1) can be used with any 

installation by fitting securely into the locating point provided. 

•  The 6 bar expansion relief valve must be fitted on the cold water supply.  

Under no circumstances should the expansion relief valve be installed in an inverted 
position as fouling of the seat caused by deposits may prevent it from operating correctly. 
The safety relief valve connections should not be used for any other purpose and no 
valve should be fitted between the expansion relief valve and the storage cylinder.

•  The installations must comply fully with UK Water Regulations, Building regulations 

part G3 and any Local Authority requirements. The point of discharge must be in a 
safe and visible position. The connection should be made using 15mm pipe having a 
continuous fall to a maximum length of 3 metres. It shall not have more than 3 right-
angled bends. If a waste connection in excess of 3 metres is necessary, the pipe 
diameter should be 22mm with continuous fall  and no more than 4 right-angled 
bends with a maximum resistance to flow equivalent to 9 metres of straight pipe.

•  An isolating valve must be fitted to the cold water supply.
•  Valves and fittings must be of a type required by the Water Supply Regulations. 

Requirements

INSTALLATION

Содержание AQUAPOINT III AP3/05

Страница 1: ...0 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP AQUAPOINTIII INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER AP3 05 AP3 15...

Страница 2: ...ation 14 Maintenance 15 Precautions 15 Schedule 16 De installation 16 Fault finding 17 End of life disposal 18 Warranty 19 Contact details 20 Please read these instructions carefully before commencing...

Страница 3: ...nti corrosion protection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting...

Страница 4: ...ic precautions See installation and operating instructions Smart value 0 Rated volume l 6 2 6 6 9 8 9 9 14 8 14 9 Weight empty full kg 6 5 13 5 8 5 18 5 9 8 24 7 Power rating W 2 000 Nominal supply vo...

Страница 5: ...the appliance See Technical data page 4 The connecting cable must be adequately secured This appliance must be earthed at all times Check that the power supply is switched off prior to electrical con...

Страница 6: ...rking order The appliance must be installed in a frost free room and must never be exposed to frost The appliance must be completely filled with water before the electrical supply is switched on The A...

Страница 7: ...2 11 REF ITEM DESCRIPTION 1 AQ0330 Element 2 AQ0331 Gasket 3 AQ0332 Control knob lens 4 AQ0333 Thermostat 5 AQ0334 Resettable cut out 6 AQ0335 Sacrificial anode 10 15 litre 7 AQ0347 Sacrificial anode...

Страница 8: ...heck that the items listed below have been supplied in the Aquapoint III pack ITEM QTY Wall Bracket 1 Fixing Screws 2 Rawl plugs 2 Expansion Relief Valve 1 2 BSP 1 AQ1 Temperature and pressure relief...

Страница 9: ...essures are likely to exceed 3 5 bar fit accessory pack AQ2 and AQ3 pressure reducing valve and line strainer See diagrams 2 3 Fig 2 page 12 If required a temperature and pressure relief valve accesso...

Страница 10: ...of water see Technical data page 4 The undersink unit can be placed unsupported on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear...

Страница 11: ...ine the accessories required to suit your layout Position the heater and controls to allow for future maintenance All control and safety valves are marked with the direction of flow and will not funct...

Страница 12: ...reducing valve COLD WATER SUPPLY TO DRAIN VIA TUNDISH Length A COLD WATER DRAW OFF Minimum length of pipe Length A 5 Litres 1 2m 4ft 0 6m 2ft 10 Litres 2 7m 9ft 1 2m 4ft 15 Litres 4 2m 14ft 1 8m 6ft S...

Страница 13: ...a minimum break rating of 13 amps If the cable length is insufficient it is recommended that the entire length of cable is replaced with no joins to the original To replace the cable Prise the tempera...

Страница 14: ...quired position The economy e setting will maintain the most economical stored water temperature at approx 41 C for models AP 05 OB AP3 05 or 35 C for models AP3 10 OB AP3 10 AP3 15 OB AP3 15 Lime sca...

Страница 15: ...supply The over temperature safety cut out reset is located inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected DO...

Страница 16: ...eck the condition of the anode electrically disconnect the wire between the anode and the vessel and check that the current between anode and vessel exceeds 0 4mA Ensure that the wire is reconnected a...

Страница 17: ...e commission Thermostat failure Isolate the heating system and check the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water dis charge from tundish Pressure reduc...

Страница 18: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Страница 19: ...t of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its distributor This warranty does not cover damage resulting from non operat...

Страница 20: ...005 V2 00 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Отзывы: