background image

5

INSTALLATION INSTRUCTIONS & USER MANUAL 

210005 V2.00 AUG 2017 - ZIP APIII/5-15(OB)

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

(1) EU Regulation 812/2013;EN 50440
(2) Temperature control ‘e’ setting corresponds to approx. 41°C for models AP3/05/0B, AP3/05 or 35°C for models AP3/10/OB, AP3/10, AP3/15/OB, AP3/15.

Safety Information

WARNINGS

 

•   Installation, commissioning and maintenance of this appliance must only be carried 

out by a competent installer who will then be responsible for adhering to all relevant 
standards and regulations.

•   The appliance must be disconnected from mains power supply before carrying out 

any work involving live circuits.

•   The appliance must be permanently connected to the supply through an isolating switch 

with a contact separation of at least 3mm in all poles and be protected by a suitably rated 
RCD.

•   To protect the appliance, an MCB (miniature circuit breaker) or cartridge fuse must be 

fitted with a rating suitable for the nomi nal current of the appliance.

•   The cross sectional area of the connection cable must be appropriate for the power rating 

and location of the appliance. See Technical data, page 4. 

•   The connecting cable must be adequately secured.
•   

 This appliance must be earthed at all times.

•   Check that the power supply is switched off prior to electrical connection.
•   The appliance, its wiring and piping must not be modified in any way.
•   In case of malfunction isolate the power supply immediately. In case of leaks also isolate 

the water supply. Repairs must only be carried out by a competent person.

•   Temperatures in excess of approximately 43°C are perceived as hot, especially by children, 

and may cause a feeling of burning. 

SAFETY INFORMATION

WARNING:

Indicates a potentially hazardous situation, which, if not avoided, 
could result in death and/or serious injury and/or property 
damage.

CAUTION:

Indicates a potentially hazardous situation, which, if not avoided, 
may result in property damage. 

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. 
NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT 
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO 
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. RETAIN 
THESE INSTRUCTIONS FOR FUTURE USE.

Содержание AQUAPOINT III AP3/05

Страница 1: ...0 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP AQUAPOINTIII INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER AP3 05 AP3 15...

Страница 2: ...ation 14 Maintenance 15 Precautions 15 Schedule 16 De installation 16 Fault finding 17 End of life disposal 18 Warranty 19 Contact details 20 Please read these instructions carefully before commencing...

Страница 3: ...nti corrosion protection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting...

Страница 4: ...ic precautions See installation and operating instructions Smart value 0 Rated volume l 6 2 6 6 9 8 9 9 14 8 14 9 Weight empty full kg 6 5 13 5 8 5 18 5 9 8 24 7 Power rating W 2 000 Nominal supply vo...

Страница 5: ...the appliance See Technical data page 4 The connecting cable must be adequately secured This appliance must be earthed at all times Check that the power supply is switched off prior to electrical con...

Страница 6: ...rking order The appliance must be installed in a frost free room and must never be exposed to frost The appliance must be completely filled with water before the electrical supply is switched on The A...

Страница 7: ...2 11 REF ITEM DESCRIPTION 1 AQ0330 Element 2 AQ0331 Gasket 3 AQ0332 Control knob lens 4 AQ0333 Thermostat 5 AQ0334 Resettable cut out 6 AQ0335 Sacrificial anode 10 15 litre 7 AQ0347 Sacrificial anode...

Страница 8: ...heck that the items listed below have been supplied in the Aquapoint III pack ITEM QTY Wall Bracket 1 Fixing Screws 2 Rawl plugs 2 Expansion Relief Valve 1 2 BSP 1 AQ1 Temperature and pressure relief...

Страница 9: ...essures are likely to exceed 3 5 bar fit accessory pack AQ2 and AQ3 pressure reducing valve and line strainer See diagrams 2 3 Fig 2 page 12 If required a temperature and pressure relief valve accesso...

Страница 10: ...of water see Technical data page 4 The undersink unit can be placed unsupported on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear...

Страница 11: ...ine the accessories required to suit your layout Position the heater and controls to allow for future maintenance All control and safety valves are marked with the direction of flow and will not funct...

Страница 12: ...reducing valve COLD WATER SUPPLY TO DRAIN VIA TUNDISH Length A COLD WATER DRAW OFF Minimum length of pipe Length A 5 Litres 1 2m 4ft 0 6m 2ft 10 Litres 2 7m 9ft 1 2m 4ft 15 Litres 4 2m 14ft 1 8m 6ft S...

Страница 13: ...a minimum break rating of 13 amps If the cable length is insufficient it is recommended that the entire length of cable is replaced with no joins to the original To replace the cable Prise the tempera...

Страница 14: ...quired position The economy e setting will maintain the most economical stored water temperature at approx 41 C for models AP 05 OB AP3 05 or 35 C for models AP3 10 OB AP3 10 AP3 15 OB AP3 15 Lime sca...

Страница 15: ...supply The over temperature safety cut out reset is located inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected DO...

Страница 16: ...eck the condition of the anode electrically disconnect the wire between the anode and the vessel and check that the current between anode and vessel exceeds 0 4mA Ensure that the wire is reconnected a...

Страница 17: ...e commission Thermostat failure Isolate the heating system and check the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water dis charge from tundish Pressure reduc...

Страница 18: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Страница 19: ...t of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its distributor This warranty does not cover damage resulting from non operat...

Страница 20: ...005 V2 00 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Отзывы: