 Instructions. V1.01 

Page 13  

 JULY / 2013

9.  Switch on the electrical supply to the unit. The red neon light will glow during the heating 

cycle and will extinguish when the selected temperature is reached re-lighting again for 
the next heating cycle. 

10.  During the heating cycle no water should escape to waste from either the expansion 

relief or T&P valves.

11.  Allow the heater to reach the selected temperature and when the indicator light has 

extinguished, check the water temperature and re-check the water connections 
adjusting as necessary.

12.  Please pass these instructions on the person responsible for the building and it’s 

management.

Maintenance

Precautions

1.  The Zip Aquapoint III is an unvented electric water heater and only a competent person 

(electrician or plumber), familiar with unvented systems, should carry out any servicing 
and maintenance work on this unit.

2.  DO NOT Remove the cover whilst the unit is connected to the electrical supply. 

WARNING

 

 

When the neon indicator light is extinguished the unit is still connected 

to the electrical supply, only by operating the ‘double pole isolating switch’ can the unit 
be disconnected from the supply.

3.  The over temperature safety cut-out reset is located inside the cover. DO NOT reset the 

over temperature cut-out until the cause of it’s operation has been correctly diagnosed 
and corrected.

4.  DO NOT use the water heater if it is suspected of being frozen. Switch off the electrical 

supply if water ceases to flow and do not switch it back on until a competent person 

(electrician or plumber), has checked that it is safe to do so.

5.  The heater should be visually inspected regularly. This is particularly important if the 

heater is located in a cupboard, roof space or any other concealed location. If there are 
any signs of leaks or seepage the heater should be isolated from the water supply and 
switched off from the electrical supply until a competent person (electrician or plumber), 
has investigated the cause.

6.  DO NOT block or restrict the discharge from any safety valve.
7.  DO NOT tamper with any safety valve.
8.  If water discharges from any safety valve, switch off the electrical supply to the unit, 

isolate the water supply and contact a competent person (electrician or plumber) 
familiar with unvented systems.

9.  Please note that limescale forms more readily at higher temperatures. Damage or 

failures caused by the formation of limescale  are specifically excluded under the 

terms of the warranty. To reduce limescale formation to a minimum the unit should 
always be operated at the lowest convenient temperature. The ‘E’ temperature setting 
is recommended.

Содержание AP3/05

Страница 1: ...e instructions carefully before commencing installation of this unvented water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham...

Страница 2: ...inside front cover inside back cover...

Страница 3: ...nd when correctly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The products are listed under the WRAS Water Regulations Advisory Scheme Water Fitting...

Страница 4: ...fitted to the vessel to provide anti corrosion protection for the vessel and the heating element Description Gradual erosion of the anode will occur depending on local conditions and in extreme cases...

Страница 5: ...e appliance its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carrie...

Страница 6: ...0845 6 005 005 for advice Zip Heaters UK Ltd cannot be held liable for any damages caused by failure to observe these instructions It is recommended that an HE45004 Water Block is fitted in the water...

Страница 7: ...pacity 6 Litre 10 Litre 15 Litre Weight kg Full 12 7 18 5 24 8 Weight kg Empty 6 7 8 5 9 8 Heat up time 15 C to 65 C 11 mins 18 mins 32 mins Re heat time 70 vol 7 mins 12 mins 18 mins Heat Loss kWh 24...

Страница 8: ...rol knob lens AQ0332 4 Thermostat AQ0333 5 Resettable cut out AQ0334 6 Sacrificial anode 10 15 litre AQ0335 7 Sacrificial anode 5 litre AQ0347 8 Indicator light AQ0336 9 Control knob with spring AQ033...

Страница 9: ...2 and AQ3 pressure reducing valve and line strainer see diagrams 2 3 fig2 page 10 6 If required a temperature and pressure relief valve accessory AQ1 can be used with any installation by fitting secur...

Страница 10: ...laced unsupported on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear of the casing As shown in fig 1 4 Always position the Zip Aqu...

Страница 11: ...s Do not use plumbers paste to secure the joints as this can impair the operation of any valves connected to the heater 6 An isolating service valve not supplied should be fitted in the cold water sup...

Страница 12: ...1 NEAREST COLD WATER DRAW OFF HOT COLD EXPANSION RELIEF VALVE EXPANSION VESSEL SERVICE VALVE CHECK VALVE PRESSURE REDUCING VALVE DIAGRAM 3 Inlet pressure greater than 0 35 MPa 3 5 bar Using pack AQ2...

Страница 13: ...ole switched spur 2 If the cable length is insufficient it is recommended that the entire length of cable is replaced with no joins to the original To replace the cable a a Prise the temperature contr...

Страница 14: ...h a water temperature of 55 C is recommended for economical operation while minimising lime scale deposits and thermal losses Note Rotating the temperature control knob varies the temperature over the...

Страница 15: ...cated inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected 4 DO NOT use the water heater if it is suspected of being...

Страница 16: ...connect the wire between the anode and the vessel and check that the current between anode and vessel exceeds 0 4mA Ensure that the wire is reconnected afterwards If the current between the anode and...

Страница 17: ...the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water discharge from tundish Pressure reducing valve not operating correctly Check with pressure gauge and repla...

Страница 18: ...Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner...

Отзывы: