Electrical installation & wiring
It is recommended that the electrical installation is carried out by a qualified electrician.
It is essential that the electrical installation including earthing and cross bonding should
be carried out to comply with the current IEE regulations and local council requirements.
WARNING:
SWITCH OFF THE MAINS ELECTRICAL SUPPLY
BEFORE CARRYING OUT ANY WORK INVOLVING A LIVE CIRCUIT.
230v AC SUPPLY ONLY, THIS APPLIANCE MUST BE EARTHED.
BROWN
BLUE
GREEN/YELLOW
LIVE
NEUTRAL
HEATING ELEMENT
THERMOSTAT
NEON
INDICATOR BULB
EARTH
Supply through a
Fused doublepole
switch or fused
spur.
OVER TEMPERATURE
SAFETY CUT-OUT
1. The Zip Aquapoint III is pre-wired with a length of 3 core cable suitable for connection
to a mains 230v supply. Connection must be made in accordance with the current IEE
wiring regulations to a double pole isolating switch on a dedicated circuit or a double
pole switched spur.
2.
If the cable length is insufficient it is recommended that the entire length of cable is
replaced with no joins to the original. To replace the cable:
)
a Prise the temperature control knob off the spindle and remove the screw underneath.
)
b
Release the two fixing screws at the top of the cover assembly.
)
c Remove the cover by lifting forwards and upwards.
)
d Release the locknut on the cable grommet assembly.
)
e Remove the existing cable and pass the new cable through the grommet assembly.
)f Remake the cable connections and tighten the grommet locknut to ensure the cable is
securely clamped
)
g Re-assemble the cover.
3.
All internal wiring is factory mounted and should not be altered or modified.
This appliance must be earthed.
Do not switch on the electrical supply until the water heater is full of water.
Safety Cut-out
In the event of a malfunction that leads to an over temperature situation, a Safety cut out
will automatically cut off the electrical supply to the element.
This is a manually resettable cut-out that may be reset by a qualified electrician once the
fault has been corrected.
Wiring Diagram