Plumbing

1.  Check the incoming water supply pressure as this will determine the layout 

and safety controls required. Remember that the mains water pressure can 
increase considerably at night.

2.  Refer to diagrams 1 to 3 to determine accessories required and layout.

3.  Position the heater and controls to allow for future maintenance.

4.  All control and safety valves are marked to show the direction of water

flow and will not function if incorrectly orientated. Do not break any seals or
attempt to adjust any safety valve; to do so may impair the safety of the
installation and will invalidate the warranty.

5.  To ensure a watertight seal use fibre washers for connecting the inlet

and outlet pipes to the heater. Complete the seal by applying PTFE tape
to the threads but do not over-apply or extend beyond the limits of the
thread as this will lessen the effectiveness of the joint. Do not use plumbers
paste to secure joints as this can impair the operation of any valves
connected to the heater.

6.  An isolating service valve (not supplied) should be fitted in the cold water

supply pipe-work as shown in diagrams 1 to 3. 

7.  Flush all pipe work thoroughly before making the final connections to the

valves, accessories and cold feed to the heater to ensure that any debris is
removed. Failure to do this may result in irreparable damage to the controls
and will invalidate the warranty.

Electrical

1.  Switch off the mains electrical supply before carrying out any work involving 

a live circuit or access to components that may be live.

2.  The Zip Aquapoint is pre-wired with a length of 3 core cable suitable for

connection to a mains 240v supply. Connection must be made in
accordance with current IEE wiring regulations to a double pole isolating 
switch on a dedicated circuit or a double pole switched spur.

3.  If the cable length is insufficient it is recommended that the entire length is

replaced and no joins made to the original. To replace the cable:

a.  Prise the temperature control knob off the spindle and remove the fixing 

screw located beneath

b.  Release the two fixing screws at the top of the cover assembly

c.  Remove the cover by lifting forwards and upwards

d.  Release the locknut on the cable grommet assembly

AP3/05, AP3/10, AP3/15 Installation Instructions                                               

New Aquapoint lll qxd:New Aquapoint lll qxd  5/11/08  15:51  Page 8

Содержание AP3/05

Страница 1: ...The terms Zip and Aquapoint are registered trademarks Zip products described in the brochure are manufuctured under one or more of the following patents AU675601 AU637412 AU635979 GBO422305 GB2065848...

Страница 2: ...tion 12 Fault Finding 13 Warranty 14 Installation must only be undertaken by a competent person familiar with unvented electric water heaters The Zip Aquapoint must be installed in accordance with the...

Страница 3: ...nt Approvals Zip Aquapoint III complies with LVD and EMC directives and is CE endorsed Zip Aquapoint III has been exam ined tested and found when correctly fitted to comply with the requirements of th...

Страница 4: ...602 4533 The Zip Aquapoint is an unvented water heater designed for connection directly to the incoming mains water supply and can serve one or more outlets using conventional taps Care should be take...

Страница 5: ...nstallation If in doubt or in need of further guidance please call Zip Customer Service on 0845 602 4533 2 Zip Aquapoint unvented water heaters must be installed by a competent installer familiar with...

Страница 6: ...with a maximum resistance to flow equivalent to 9 metres of straight pipe 9 An isolating valve must be fitted to the cold water supply 10 Valves and fittings must be of a type required by Water Supply...

Страница 7: ...l shown Diagram 1 Inlet pressure less than 4 bar and expanded hot water can be accommodated in the pipe work Diagram 2 Inlet pressure less than 4 bar but expanded hot water cannot be accommodated in t...

Страница 8: ...d water supply pipe work as shown in diagrams 1 to 3 7 Flush all pipe work thoroughly before making the final connections to the valves accessories and cold feed to the heater to ensure that any debri...

Страница 9: ...to ensure free water flow through the discharge pipe by turning the knob to the left and holding in the open position 9 Set the temperature control knob to the desired position The E position with a...

Страница 10: ...space or any other concealed location If there is any sign of leaks or seepage the heater should be isolated from the water supply and switched off from the electrical supply until a competent person...

Страница 11: ...unscrewing the element assembly and removing it If the anode is badly corroded it should be replaced after removing it by grasping with long tongs or other suitable tool through the flange opening wh...

Страница 12: ...aulty element Thermostat failure Solution Reset If the cut out operates again isolate the unit and contact the installer NB Isolate the electrical supply before removing the electrical cover panel and...

Страница 13: ...and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance...

Отзывы: