AP3/05, AP3/10, AP3/15 Installation Instructions                                               

5  

Dimensions

Model

Capacity

Dimensions

Fixing Centres

Weight

Water

(litres)

(mm)

(mm)

(kg)

Connections

A       B        C        D        E

F     Empty Full

AP3/05 (OB)

6         376    256    260    100     252      140       6.7     12.7      

1/2"

BSP

AP3/10 (OB)

10        480    350    265    100     378      140       8.5     18.5      

1/2"

BSP

AP3/15 (OB)

15        480    350    310    100     378      140

9.8     24.8      

1/2"

BSP

Special notices

These instructions should guide you through the installation, maintenance and
use of the Zip Aquapoint III, however, if you require any further information
please call Zip Customer Service on 0845 602 4533.

The Zip Aquapoint is an unvented water heater designed for connection
directly to the incoming mains water supply and can serve one or more
outlets using conventional taps.

Care should be taken that the capacity of the unit chosen is sufficient to
meet the demands of the outlets being supplied.

The casing is constructed from impact resistant plastic and heat losses are
minimised by the high efficiency polyurethane foam insulation.

The inner vessel is constructed from glass enamelled steel sheet and
pressure tested to 12 bar.

A manually re-settable safety cut-out automatically cuts off the electrical 
supply to the heating element in the event of a malfunction.

New Aquapoint lll qxd:New Aquapoint lll qxd  5/11/08  15:51  Page 4

Содержание AP3/05

Страница 1: ...The terms Zip and Aquapoint are registered trademarks Zip products described in the brochure are manufuctured under one or more of the following patents AU675601 AU637412 AU635979 GBO422305 GB2065848...

Страница 2: ...tion 12 Fault Finding 13 Warranty 14 Installation must only be undertaken by a competent person familiar with unvented electric water heaters The Zip Aquapoint must be installed in accordance with the...

Страница 3: ...nt Approvals Zip Aquapoint III complies with LVD and EMC directives and is CE endorsed Zip Aquapoint III has been exam ined tested and found when correctly fitted to comply with the requirements of th...

Страница 4: ...602 4533 The Zip Aquapoint is an unvented water heater designed for connection directly to the incoming mains water supply and can serve one or more outlets using conventional taps Care should be take...

Страница 5: ...nstallation If in doubt or in need of further guidance please call Zip Customer Service on 0845 602 4533 2 Zip Aquapoint unvented water heaters must be installed by a competent installer familiar with...

Страница 6: ...with a maximum resistance to flow equivalent to 9 metres of straight pipe 9 An isolating valve must be fitted to the cold water supply 10 Valves and fittings must be of a type required by Water Supply...

Страница 7: ...l shown Diagram 1 Inlet pressure less than 4 bar and expanded hot water can be accommodated in the pipe work Diagram 2 Inlet pressure less than 4 bar but expanded hot water cannot be accommodated in t...

Страница 8: ...d water supply pipe work as shown in diagrams 1 to 3 7 Flush all pipe work thoroughly before making the final connections to the valves accessories and cold feed to the heater to ensure that any debri...

Страница 9: ...to ensure free water flow through the discharge pipe by turning the knob to the left and holding in the open position 9 Set the temperature control knob to the desired position The E position with a...

Страница 10: ...space or any other concealed location If there is any sign of leaks or seepage the heater should be isolated from the water supply and switched off from the electrical supply until a competent person...

Страница 11: ...unscrewing the element assembly and removing it If the anode is badly corroded it should be replaced after removing it by grasping with long tongs or other suitable tool through the flange opening wh...

Страница 12: ...aulty element Thermostat failure Solution Reset If the cut out operates again isolate the unit and contact the installer NB Isolate the electrical supply before removing the electrical cover panel and...

Страница 13: ...and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance...

Отзывы: