Page 8 of 16 

Zip Hydroboil Plus - Installation & Operating Instructions - 89956UK - January 2012 v1.04

Tap Operating Procedures

Tap Operation

Safety feature.

Zip Hydroboil Plus has a unique safety device designed to reduce the incidence of accidental operation of the tap.The 
tap can be “Locked” to prevent the Hydroboil Plus from dispensing hot water

In order to “lock” the tap, ensure the safety button is protruding from the right hand side of the control panel and the 
locked indicator is illuminated 

This can be achieved by pressing the button and simultaneously rotating it until the groove in the head of the button 
faces  toward the body of the appliance. In this position an internal spring will push the button out. Once the button is in 
the extended position, the tap will be “Locked” and unable to dispense hot water.

Disengage safety feature.

Press and simultaneously rotate (aprox 90 degrees) the safety button on the right hand side of the control panel, until it 
latches in the closed position, and the unlocked indicator is illuminated. 

Warning: The unit is now capable of dispensing boiling water without the safety feature. 

Dispensing Boiling water:

Zip Hydroboil Plus is fitted with a  safety, two-way cool-touch safety tap for instant boiling water. 

Normal operation

 (for filling cups and small containers)

To activate the tap, press the safety button on the right side of the control panel and while holding the button in, gently 
push the lower end of the tap paddle inwards and boiling water will flow until the tap paddle is released. 

Continuous operation

 (for filling, tea pots, saucepans and large containers )

Press the safety button on the right side of the control panel and while holding the button in, Lift the tap paddle until it 
locks into a horizontal position, the button can now be released and boiling water will flow until the paddle is returned 
to its normal vertical position. This operation allows a vessel to be filled without holding your hand where it may be 
affected by steam.

Normal operation

Continuous operation

locked

Press to unlock

Press to unlock

Locked / unlocked indicators

Содержание 89956UK

Страница 1: ...droboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Page 1 of 16 Installation and Operating Instructions Zip Hydroboil Plus Large boiling water Affix Model Number Label Here 89...

Страница 2: ...Page 2 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 This page intentionally left blank...

Страница 3: ...Read these warnings first 4 Installation Requirements 4 5 Installation Procedures 5 7 Step 1 Positioning 5 Step 2 Fastening 5 See page 6 Wall Mounting Template Dimensions Step 3 Connecting 6 a Plumbi...

Страница 4: ...g the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall...

Страница 5: ...tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm l...

Страница 6: ...dversely affect the operation of the heater The heater must be installed with an isolating valve which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum...

Страница 7: ...outlet Turn power ON After a short period boiling water will be available and will be maintained close to boiling point thereafter Initial heating periods are shown in the table on the left Warning t...

Страница 8: ...panel until it latches in the closed position and the unlocked indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water...

Страница 9: ...n have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time cloc...

Страница 10: ...the ambient light in the room where the Hydroboil Plus is installed drops below 100lux the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be mainta...

Страница 11: ...2 To increment the Minutes press CSS3 To step to the next configuration parameter press CSS1 SET DAY OF THE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CS...

Страница 12: ...Light sensor is configured as on pressing CSS1 will return the user to Normal Operation Note 3 If both Sleep Mode and Low Light sensor is configured as off the user will be able to use ON OFF mode SUN...

Страница 13: ...rrectly Please contact your local city council for collection centre details Problem Solving Sympton Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter blo...

Страница 14: ...9 90102UK Cistern Float S Nut Kit 10 90495UK Banjo Screw Kit 11 90174UK Contactor Kit 12 90743UK Fascia Lens 13 90994UK Fascia Assy Electronic White 13 90995UK Fascia Assy Electronic Grey 14 90620UK...

Страница 15: ...Page 15 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Spare Parts 7 RQQHFWRU 6 RQQHFWRU 21 IRU Contactor Only for 40L...

Страница 16: ...tration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot...

Отзывы: