background image

8

Installation instructions 

805845UK  V1.02 July 2018 - G4 Command Centre

Technical support

  

Tel: 0345 6 005 005  Email: [email protected]  www.zipwater.co.uk

Major components and accessories

Accessories

Description

Booster 

(inc. connection 

hoses)

Scale, taste & 

odour filter

Scale filter

installation kit 

(Filter not included). 

Font, Integrated or 

Stand alone

Replacement  

internal 0.2 micron 

filter

Disabled lever kit

(Classic HydroTap)

Mixer upgrade

All-in-One upgrade

(vented)

(mains)

Recommended  

water block     

Parts supplied

Description

Tap options*

1 x HydroTap

 

G4

1 x All-in-One 

 HydroTap

 

G4 

Mains or Vented

1 x mixer tap

Command Centre and components

Duct kit*

1 x Exhaust duct

1 x Mounting plate

2 x Outlet vent

1 x Inlet vent

1 x

Command Centre 

with air and water 

filters

1  x  Mains  water            

connection hose

1 x Booster inc. 

connection hoses 

(supplied with 

140 or 240 models)

1 x Installation 

fittings (supplied 

with vented mixer 

tap models)

1 x User guide and 

1 x Quick start guide

1 x Installation 

instruction

801599 - HydroTap User Guide - Nov 2013 UK - V1.05

Page 1 of 20

ZIP HydroTap

User Guide

®

Tap Operation...................(Pages 2-5)

LCD Screen & Menu .......(Pages 6-18)

Maintenance.................... (Pages 18-20)

Date of Installation.........

Affix Model Number Label 

Here

 801599

BC160/125G4

BC240/175G4

BCH160/125G4

BCH240/175G4

AV160/125G4

AN160/125G4

AV240/175G4

AN240/175G4

801600 - Zip Quick Start Guide - October 2013 - V1.06

Parts Supplied

Description

Parts Supplied

Description

1 off

Hydrotap Tap

and hoses

Duct kit

1x Air Duct

1 x Mounting 

plate

1 off

Undersink Unit 

with air and water-

filter

Vent kit

1 x Kickboard 

louvre

1 x Door vent 

louvre

1 x front vent grill

1 x Restrictaflow 

valve and Tee 

piece for Mixer 

Taps

1 off

HydroTap 

Booster heater 

and hoses

(Supplied with 

240/175 models)

1 off Mains water 

connection hose

QUICK START GUIDE

Note: This quick start guide must be read in conjunction with 

the main installation and user instructions 

• 

Before proceeding, read the installation and user instructions

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools

• 

Ensure the underbench can support the product weight when full of water,                                   

(Check the specifications in the main book and allow an extra 5-8kg when full. )

Before installing ensure the following have been provided at 

the installation site:

• 

Sufficient space in the cupboard to install all of the undersink units in accordance 

with these Installation Instructions. Refer to technical specification for dimensions. If 

required, make allowance for a booster heater. (Refer to the main book, for detailed 

installation instructions). 

• 

A potable water supply connection with isolating valve inside the cupboard within 

reach of the flexible braided hose and positioned so that the connection point and the 

stop cock will not be obstructed when all the undersink units are installed. 

• 

For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be 

required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be 

required. (One GPO is for the Zip HydroTap and the other for the Booster heater).                                                                                                                         

NOTE: Check the cable lengths and outlet positions before proceeding. 

• 

A potable cold water supply with a minimum working pressure of 172kPa and a 

maximum working pressure of 700kPa connected via an isolation valve. 

• 

For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.

• 

The undersink appliances must be mounted in upright positions as shown in the 

diagrams. 

IMPORTANT!

  Do not proceed with the installation if these 

requirements are not met.

STEP 1- 

Prepare and fit the Taps

Hole positioning: 

Position the tap such that it dispenses into 

the sink bowl with ample clearance for a cup or tea pot. Alternatively, 

the tap could be mounted away from the sink using a Zip Font, avail-

able as an accessory.

Apply a light smearing of silicon sealant 

on the underside of the upper spacer to 

ensure a watertight fi t.

For HydroTap and Mixer taps 

cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

HydroTap Tap

Mixer Tap 

4-in-1

 

(If required)

NUT

LOWER RUBBER 

WASHER

UPPER 

RUBBER 

WASHER

WASHER

BRAIDED 

HOSE x 3

UPPER RUB-

BER WASHER

LOWER RUB-

BER WASHER

WASHER

NUT

White Hose

Ext. Mains

Blue band

Mixer  IN

Red band

Mixer Out 

O-RING

BASE 

BLOCK  

SPIDER

BASE 

BLOCK 

NUT

USB 

CABLE

ALL 

THREAD 

ROD

NOTE: feed each of 

the tubes and elec-

trical cable evenly in 

between the legs of 

the BASE BLOCK 

SPIDER.

All-In-One Tap 

(If required)

For AIO mains and vented Taps

Cut a 50mm hole in the bench / sink top.

NOTE: make sure the tap location will allow the nozzle to drain into the sink. 

SINK TOP

50mm

ALL THREAD 

ROD

STAINLESS 

STEEL  

WASHER

SPIDER 

CLAMP

NUT

BLACK 

PLASTIC 

SPACER

NOTE: feed each of the three tubes and 

electrical cable evenly in between the legs of 

the SPIDER CLAMP when installing. 

Fit the 

STAINLESS STEEL           

WASHER, 

SPIDER CLAMP, 

AND 6mm NUT.  

6mm 

NUT

SPIDER 

CLAMP

Stainless 

washer

Black plastic 

spacer

35mm dia hole

Sink

O-RING

SINK TOP

Fit the O-ring to the underside of the AIO tap 

then pass all hoses through the 50mm hole. 

Chiller 

connection 

BLUE

From 

Mixer OUT

 to Tap - Vented version only

Boiler 

connection 

RED

Blue ring on 

RHS mains IN to

       

Mixer IN

White ring

on LHS to 

Mains in

Tap

O ring Base

Clear tube to Vent

For Accessories contact Zip:
Tel 0345 6 005 005
Website: www.zipwater.co.uk

Email: [email protected]

*Dependant on model purchased

Содержание 5253UK

Страница 1: ...Tel 03456 005005 Email service zipindustries co uk www zipwater co uk VENTILATION ISESSENTIAL READSECTION1 VENTILATION BEFOREYOUSTART Installationinstructions Zip HydroTap G4 TheWorldsmostadvancedDri...

Страница 2: ...sparkling water and are directly compatible with the G4 Command Centre The All in One tap may be used as alternatives to the above HydroTap and mixer tap combinations The mixer tap range may be used...

Страница 3: ...nd Centre Section 7 Commercial residential Command Centre installation Section 7 1 Generic Command Centre installation instructions 30 Section 7 2 External bypass valve 31 Section 7 3 5253UK 5053UK BC...

Страница 4: ...the under counter cupboard floor supporting the Command Centre is adequate for its total weight when full of water Before commissioning Check the system has been installed correctly Check all plumbin...

Страница 5: ...he HydroTap G4 utilises a conventional refrigerant compressor to chill the water and an immersion heating element to boil the water These units are NOT designed to be used solely as sanitary fixtures...

Страница 6: ...ble is damaged it must be repaired only by a qualified technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet...

Страница 7: ...roTap G4 is rated for 230V 50 60Hz AC operation supply frequency dependant upon model purchased Do not remove the cover of the appliance under any circumstances without first isolating the appliance f...

Страница 8: ...ion instructions A potable water supply connection with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock will...

Страница 9: ...lus unfiltered Hot and Cold Filtered Chilled and Sparkling plus unfiltered Hot and Cold Celsius Arc Cube Elite Classic HydroTaps Mixer taps Classic Vented Filtered Boiling Filtered Boiling and Ambient...

Страница 10: ...e taps All in One Classic Vented Arc Cube Elite Classic HydroTaps Mixer taps Arc Mains Cube Mains Filtered Boiling Filtered Boiling and Ambient Filtered Boiling and Chilled Filtered Boiling Chilled an...

Страница 11: ...1 2 280 x 313 x 335 11 Filtered Chilled and Sparkling 0053UK 175 0 45 1 336 x 476 x 335 36 Filtered Chilled 0061UK 175 0 3 1 336 x 480 x 335 24 Residential Command Centres Filtered Boiling Chilled an...

Страница 12: ...oth the Command Centre and booster must be installed in accordance with IEE regulations See Technical specification page 11 for power ratings Note Check all cable and hose lengths against inlet outlet...

Страница 13: ...allation 17 1 5 CS C Commercial Command Centre installation 18 1 6 BC BCS CS C Residential Command Centre installation 20 Generic requirements Important Read this section in conjunction with section 7...

Страница 14: ...lle Position vent grille on either the kick board or the cupboard ends Inlet grille should be fitted in baseboard A Cupboard back must be fully closed to prevent recirculation into cupboard from kick...

Страница 15: ...on B2 and without kick space duct fitted to the Command Centre For dual exhaust fan cut out dimensions see the instructions provided with the kit B A B2 B1 Vent tray 100mm min 1 2 4 Alternative arrang...

Страница 16: ...led through the top of the cupboard The outlet vent A should be towards the top of the door position A2 or side of the cupboard position A1 Where possible air inlet vent and the air outlet vent should...

Страница 17: ...cation sheets and installation instructions must be observed Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 350 C 1 4 2 Preferred arrangement 4mm d...

Страница 18: ...ts are not shown in these diagrams 1 5 1 Ventilation for all models The clearance envelope dimensions stated in the specification sheets and installation instructions must be observed Adequate ventila...

Страница 19: ...door position B1 or side position B2 and without kick space duct fitted to the Command Centre For dual exhaust fan cut out dimensions see the instructions provided with the kit B1 B2 A B 1 5 4 Altern...

Страница 20: ...possible air inlet vent and the air outlet vent should be positioned at opposite ends of the same cupboard space 1 6 1 Ventilation for all models The clearance envelope dimensions stated in the speci...

Страница 21: ...d flow rate 1 2 L min Section 2 Booster system Mount base horizontally 2 1 Product description The booster system is a compact electronically controlled auxiliary water heater It is intended to provid...

Страница 22: ...of the booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt forward Lift up Release Note Remove the wall mounting chassis from the rear of the booster for w...

Страница 23: ...n the rating plate Connect the braided hoses from the BYPASS OUT fitting on the Command Centre to the water inlet of the booster blue cap and from the outlet of the booster red cap to the BYPASS IN fi...

Страница 24: ...e separately in the following document Zip scale filter head installation and operating instructions 2017 supplied with the filter head 3 1 Mounting the filter head 3 2 Cartridge installation and flus...

Страница 25: ...ulator Remove the gas cylinder from the strap Make sure the regulator knob is turned fully clockwise to the end stop before fitting Screw the regulator clockwise onto the cylinder Be aware that some C...

Страница 26: ...king a gas connection perform a leak test to check for gas leaks between regulator and cylinder and between regulator and braided hose Stage 1 Turn the gas off Using soapy water applied with a sponge...

Страница 27: ...will ensure that the volume of water that can flow through at one time is limited to a pre determined maximum providing the flow rate through it exceeds 2 litres per minute The Water Block also incor...

Страница 28: ...correct and that the filter screen see Fig 2 is inserted correctly with the convex surface facing towards the water supply 5 4 Installation Fig 2 Fit key to adjust flow Key Reset lever 5 5 Reset Proce...

Страница 29: ...let 6 3 Adjustment The carbonation valve has an adjustable flow rate The optimum setting for the valve is 1 6 litres minute Use a 6mm Allen key or large flat blade screwdriver to adjust the flow rate...