807062 v1.00 03.21 EB HB Install Instructions

Step 3 – Plumbing connection

Exposed plumbing connection

Connect the cold water inlet pipe from the base of the 
Hydroboil directly to the 12.7mm (½” BSP) compression fittings 
with nuts and olives supplied.
install a visible tundish and plumb to trapped waste. Ensure 
access for filter replacement is not obstructed.

CLEARANCE

ZONE

CLEARANCE

ZONE

100 min.

3L, 5L, 7.5L models: 65 min.
15L, 25L, 40L models: 150 min.

20 min.

98

COLD WATER

SUPPLY

15L, 25L, 40L

models: 150 min.

Tundish

(optional accessory)

220-240V AC

50Hz power outlet

300 

min.

3.1

Cold water inlet and vent outlet

IMPORTANT:

•  Cold water pipes must be flushed before connection to the inlet to prevent blockages from 

affecting operation of the appliance.

•  An isolation valve (not supplied) must be fitted to the water supply.
•  All Vent pipework:

•  must be installed with continuous fall.

•  must be no more than 3 metres in length.
•  must have no more than 3 right-angle bends.

V

ent

External 

tundish

3.2

Concealed 

inlet

45mm

Concealed 

vent

Concealed plumbing connection

Connect cold water pipe through the rear of the appliance 
using a 12.7mm (1/2” BSP) capillary elbow (e.g. No.63, loose nut 
elbow).
Connect vent from the concealed rear of the appliance to a 
dia12.7mm pipe. Vent outlet must be visible and discharge to a 
waste water drain.

OR

Содержание 403042

Страница 1: ...1 807062v1 0003 21EBHBInstallInstructions Installation instructions Zip Econoboil Hydroboil Onwallboilingwater Models Econoboil 3L 5L 7 5L Hydroboil 3L 5L 7 5L 10L 15L 25L 40L...

Страница 2: ...NSTRUCTIONS 3 WARNINGS PRECAUTIONS 4 TECHNICAL SPECIFICATION 5 Step 1 Positioning 6 Step 2 Fastening 7 Step 3 Plumbing connection 9 Step 4 Electrical connection 10 Step 5 Assembly 12 Step 6 Commission...

Страница 3: ...enting Occasionally steam and or boiling water may discharge through a vent outlet or the tap Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area and...

Страница 4: ...pliance under any circumstances without first isolating the appliance from the power supply 9 The cold water supply to this appliance must be potable and fall within your local authority guidelines 10...

Страница 5: ...within reach of the hose and positioned so that the valve will not be obstructed A 350 kPa 3 5 bar pressure limiting valve not supplied must be fitted if the incoming mains water pressure is likely to...

Страница 6: ...oles for concealed plumbing water inlet vent outlet and electrical 1 2 1 3 Observe clearance around the appliance for service access Mark corners of the appliance on the wall x x x x 1 1 100mm 3L 5L 7...

Страница 7: ...7 807062v1 0003 21EBHBInstallInstructions Step 2 Fastening 3 7 5 litre models 10 40 litre models Remove cover screws Remove the cover Use supplied screws to mount the appliance to the wall 2 1...

Страница 8: ...stallInstructions 3 7 5 litre models Strain relief bush cable gland Terminal block Escutcheon Tap nut Tap Concealed access 10 40 litre models Strain relief bush cable gland Concealed access Filter AU...

Страница 9: ...vent outlet IMPORTANT Coldwaterpipesmustbeflushedbeforeconnectiontotheinlettopreventblockagesfrom affectingoperationoftheappliance Anisolationvalve notsupplied mustbefittedtothewatersupply AllVentpipe...

Страница 10: ...and attach to the chassis earth male terminal An isolation switch should be installed according to AS3000 Do not turn power ON until the appliance can dispense water from the tap outlet Verify the ear...

Страница 11: ...and L2 is required Heating Element Key x x number of wires Red Red wire Blu Blue wire Blk Black wire Grn Green wire Yel Yellow wire Brn Brown wire Mains input 806010 v3 Electrical Wiring Diagram Hydro...

Страница 12: ...BInstallInstructions Step 5 Assembly Refit cover Fix with screws top and bottom Apply thread tape to thread Turn tap until it touches the lock nut and is upright Use spanner supplied to tighten the lo...

Страница 13: ...er to reach boiling set temperature 6 2 6 3 Check earthing Earthing continuity must be tested by a qualified technician using a resistance meter of minimum accuracy of 5 full scale deflection Ensure e...

Страница 14: ...ns Tap operation Hydroboil and Econoboil are fitted with a two way cool touch tap Boiling water will be dispensed Press lever to dispense boiling water Push to lock for continuous flow If lever does n...

Страница 15: ...Overload repeatedly tripping with excessive steam Overload repeatedly tripping without excessive steam Internal adjustment Contact Zip authorised agent In the event of a fault or failure isolate power...

Страница 16: ...prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2021 Zip Water Aust Pty Ltd Zip Water Aust Pty Ltd ABN 46 000 578 727 67 77 Allingham...

Отзывы: