Page 26 of 28                                 802006UK  BCS Residential User Guide - Aug 2015- V2.01

Air Inlet Filter

The HydroTap

®

G4 air filter is conveniently located on the outside of the 

condenser. The filter screen is a sliding fit in the plastic housing on the left 

hands side of the Command-Centre

TM

. The screen may be removed for 

cleaning by sliding it forward. This needs to be inspected at least quarterly, 

cleaned and replaced if damaged.

Note

 For best performance the unit should only be operated with a clean 

air filter screen, correctly fitted in place. Maintain at least a 50mm air gap 

in front of the screen at all times. Take care not to allow cloths or other soft 

materials to accidentally block the air inlet.

Warning: If the HydroTap

®

G4 

is switched off for a long period 

of time (e.g. more than a 

weekend), run water through 

the chilled water outlet for 

at least five minutes before 

consumption.

• 

Caution. 

A

 small amount of water will drip as the cartridge is removed.

•  Do not tilt the cartridge as water may spill from it if tilted.

•  Unpack replacement cartridge and remove sanitary cap, write today’s date 

where shown on the label. 

•  Avoid touching the filter o-rings and filter opening as this may cause 

bacterial contamination of the cartridge.

•  Moisten the o-rings with water, align the front cartridge label to the left (as 

shown in the “insert filter” diagram below), and push the new cartridge up 

into the filter head. 

•  Turn the cartridge a quarter turn anticlockwise until the cartridge comes 

to complete stop and is locked into position, with the front label facing 

forward.  

•  Initiate the filter flush programme by scrolling through the menu screen 

(see page 15).

•  When completed, wipe up any spills and dispose of spent filter cartridge 

and packaging thoughtfully.

•  Close the door to secure the appliance.

•  Adjust the filter settings in Section G (see page 21) litres and days used. 

  

 Filter maintenance

Slide to remove

Содержание HydroTap G4

Страница 1: ...802006UK BCS Residential User Guide Aug 2015 V2 01 Page 1 of 28 ZIP HydroTap G4 User Guide Affix model number label here 802006UK...

Страница 2: ...p safety Page 3 Tap operation Pages 4 to 9 Safety sensor calibration Page 10 Tap lights Page 10 to 11 LCD screen menu Pages 12 to 25 Filter maintenance Pages 25 to 26 Changing the CO2 cylinder Page 27...

Страница 3: ...r touch the CHILLED button Elite keep both fingers in position for a period of approximately ten seconds The safety lock indicator light will illuminate Classic flash momentarily Elite To deactivate t...

Страница 4: ...ssic Depress the red BOILING lever while simultaneously covering the safety lock button with a second finger These two actions need to occur within 2 seconds for the successful dispensing of boiling w...

Страница 5: ...essing the blue CHILLED lever allows the dispensing of chilled water Pulling forward the blue CHILLED lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds t...

Страница 6: ...he forward direction and when released will return to the off position When rotated in the reverse direction the tap operates in a POT FILL mode Water will flow from between 5 and 15 seconds This is u...

Страница 7: ...t the step The levers have to be manually returned to the off position Operate both levers together To dispense sparkling water Elite Classic Indicator light Safety Lock Arc Cube Select button Elite T...

Страница 8: ...ature will be dependant on the temperature of the incoming cold water Increase flow Decrease flow Cold Hot 3 Tap operation Classic mixer Arc mixer Cube mixer Arc Cube mixer taps Moving the lever away...

Страница 9: ...he hot direction is marked with a red dot and the cold direction with a blue dot for dispensing cold to warm water Lifting the lever up will decrease the flow rate and lowering the lever will increase...

Страница 10: ...sition Pull both levers forward Safety sensor Tap lights Blue lights Red lights Blue CHILLED water lights not available on Elite Continually illuminated This indicates that the temperature of the chil...

Страница 11: ...and Elite Filter light off This indicates the filter is operating within its normal specified lifespan Filter light flashing slowly The light will flash slowly when the filter is due for replacement a...

Страница 12: ...ble messages in status window Status Information Notes Safety OFF Product is in normal operation mode Safety ON Safety lock is activated Refer to section G Safety System Fault Product has one or more...

Страница 13: ...ling calibration Booster Purge CO2 Lux sensor calibration Start Stop Internal External Calibration options Enable Disable Start Stop C Service Password protected D Security Enable password Set passwor...

Страница 14: ...lts to check the fault information Press Event Log to view system events Press button for the previous menu Press Product Info to view the current product serial no Press button for the previous menu...

Страница 15: ...black carbon particles this is normal Once the filter flush has finished press the STOP button to display the main menu Sub menu 1 Filter flush 2 Filter reset 3 Boiling calibration 4 Booster 5 CO2 pu...

Страница 16: ...ater units may vent steam from the tap spout Take care to avoid personal injury whenever this occurs Press the MENU button for main menu Press the Install button Press the Booster button In the next s...

Страница 17: ...on for main menu Press the Install button Press the Purge CO button In the next screen press the START button to commence the purging process Wait for the water to stop flowing through the tap Wait a...

Страница 18: ...Zip technician Please contact your Zip service provider for further assistance G4 HydroTap G4 Password screen Note In UK call a licensed electrician plumber or call Zip Heaters by Telephone 0845 6 00...

Страница 19: ...etooth to operate the product remotely Not yet available LCD screen operation section F To set a password Press the MENU button for main menu Press the Security button Press Enable Password Enter a 4...

Страница 20: ...the Setting button Press the Date Time button Choose 12 hour mode or 24 hour mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Pre...

Страница 21: ...adjust filter life and edit filter usage To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 25 Filter maintenance Pre...

Страница 22: ...Hr OFF OFF OFF Lux Sensor 680 C Dark N A Sleep 680 C ON Lux Sensor OFF Dark N A OFF OFF OFF Lux Sensor or 2 Hr 680 C Dark 2 Hr Sleep 680 C ON Lux Sensor or 2 Hr OFF Dark 2 Hr OFF OFF OFF Disable N A N...

Страница 23: ...fic time To activate On Off modes Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off Modes Menu bu...

Страница 24: ...and Elite The HydroTap G4 is equipped with a safety mode that allows for additional safety protection if needed Hot isolation do not enable with Arc Cube To allow safety changes select YES on the saf...

Страница 25: ...r Open the door of the Command CenteTM Relieve system pressure via the filter flush stop cock a quick open and close will do Use the bucket to catch the discharge Grasp filter cartridge depress the re...

Страница 26: ...five minutes before consumption Caution A small amount of water will drip as the cartridge is removed Do not tilt the cartridge as water may spill from it if tilted Unpack replacement cartridge and r...

Страница 27: ...on clockwise and adjust to 2 7 bar green zone on dial Check all joints for gas leaks using a sponge and soapy water Purge the gas lines see CO2 purge page 17 Changing the CO2 cylinder General cleanin...

Страница 28: ...display this icon on the home screen See page 22 for details Heater is in off mode When this icon is displayed no power is being supplied to the heating element See page 22 for Energy Mode options Fi...